Software Calibration
1. Nozzle checking: Print the nozzle checking to check the condition of the printhead.
Make sure to turn off the Eclosion (Feather) function before doing the alignment.
2. Vertical calibration: Observe the physical alignment of printheads.
(
This step is not aligned well which will affect the following adjustment
)
Align the physical vertical position of printhead.
The first pass line is the reference; observe whether the second pass line is perfectly aligned with the first
pass line. If not, then we need to adjust the carriage plate. There are 3 situations:
1) The two pass is perfectly aligned, no need to adjust:
2) The second is on the left side of the first pass:
Adjust method:
A. Loosen the 3 screws on the carriage plate:
B. Turn the screw clockwise:
First pass
Second pass
First pass
Second pass