background image

Galaxy Manual 1/7/15 

 

Page 8 of 33 

GENERAL OPERATING INSTRUCTIONS 

 

BEFORE OPERATING THE 
MACHINE 

Read the manual carefully and completely before 
attempting to operate the unit.  This manual has 
important information for the use and safe operation 
of the machine and should be kept available at all 
times.  This machine will ensure years of 
satisfactory service if operated and maintained 
according to recommendations in this manual.  If 
additional help or information is needed, please 
contact your distributor or Prochem. 

 

Prochem carpet soil extraction machines have been 
designed with the operator in mind.  Provided you 
read the instructions relating to the care of your 
machine and follow them carefully and take 
advantage of the helpful hints and advice that we 
have passed on, you will achieve excellent cleaning 
results and very quickly pay for your investment.  A 
detailed operational guide is given in the following 
sections, however, the following important points 
must be emphasised.

 

 

FAILURE TO OBSERVE THESE 
INSTRUCTIONS MAY SERIOUSLY 
AFFECT THE PERFORMANCE OF 
THE MACHINE AND INVALIDATE 
THE WARRANTY

 

 

 

Connection instructions - The 220 - 240V AC 
models have been fitted with the appropriate 
EC type sealed power cable and 3 prong 13 
amp plug for the UK market. Ensure the 
machine is connected to a 13 amp socket 
outlet having the same configuration as the 
plug. No adapter should be used with this 
machine. Any modification to the plug type may 
be dangerous and will void the warranty. 

 

 

This equipment is intended for commercial use 
only. 
 

 

The machine was designed for use on carpet 
and upholstery extraction applications as per 
instructions and recommendations written in 
this manual. Any deviation from its proper use 
or purpose and the consequential damage that 
may occur is the sole responsibility of the end 
user.  
 

 

Disconnect the power cord from outlet before 
servicing. Do not leave machine connected to 
an electrical outlet when unattended. 
 

 

Do not immerse or use this machine in 
standing water. Such use may cause electric 
shock. 
 

 

This equipment is not designed to handle or 
use combustible/volatile substances such as 
gasoline or kerosene, in, on, or near the 
machine. The use of such materials will cause 
an extreme hazardous condition. 
 

 

Use defoamer at all times to prevent damage to 
the vacuum motor(s). 
 

 

Do not use water in excess of 170°F (76°C). 
 

 

To prevent seal damage and chemical build-up 
to the pump system, run clean water through 
the solution lines after each days use. 
 

 

All repairs must be carried out by an authorised 
Prochem distributor. 
 

 

Repairs should only be carried out by a 
qualified person. 
 

 

Do not use replacement parts other than 
genuine manufacturers parts as specified in the 
parts list. 
 

 

Do not use chemicals in the machine other 
than those supplied or approved by Prochem 
Europe limited. 
 

 

Do not use the machine as a 'dry' vacuum.

 

Always pre-vacuum carpets thoroughly with a 
separate 'dry' vacuum cleaner. 
 

 

Keep the solution tank and filter clean. Always 
use a clean bucket to fill the solution tank. 
 

 

Clean the waste tank, vacuum filter and fall-out 
tube daily.

 

Do not allow the vacuum shut-off 

filter to clog and do not restrict the free 
movement of the ball float (where fitted).   
Empty recovery tank regularly during use, do 
not wait for it to fill up and cut the vacuum 
motor out. 
 

 

Clean the drain valve regularly.

 

Lubricate the 

valve shaft, slide and PVC elbow connection 
with suitable oil or maintenance spray.   Do not 
drain the waste tank completely until the end of 
each job, as this will tend to clog the seal with 
debris and sediment. 
 

 

After use, flush through the pump, solution 
lines and waste tank with at least two gallons of 
hot water. 

 

Do not allow the machine, hoses or tools to 
freeze.

 

Freezing may seriously damage the 

pump and fittings.  Always drain solution and 
store indoors when not in use.  When in transit 
during freezing weather, insulate and cover 
machine, wand and hoses. To prevent hose 
cuffs splitting in cold conditions, immerse them 
in warm water before use.

Содержание AX500

Страница 1: ...Galaxy Manual 1 7 15 Page 1 of 33 Galaxy CARPET SOIL EXTRACTOR SAFETY OPERATION MAINTENANCE INSTRUCTIONS MODELS AX500 GALAXY CAUTION READ THE INSTRUCTION MANUAL BEFORE USING THE APPLIANCE...

Страница 2: ...prochem co uk Website www prochem co uk All information and specifications in this manual are current at the date of issue However because of Prochem Europe policy of continual product improvement we...

Страница 3: ...TIONS 8 UNDERSTANDING YOUR SOIL EXTRACTOR 9 ACCESSORIES CHEMICALS 10 CONDENSED OPERATING INSTRUCTIONS 11 PRACTICAL CARPET CLEANING 12 GENERAL MAINTENANCE 13 TROUBLESHOOTING SECTION 15 DISASSEMBLY SECT...

Страница 4: ...r information regarding the disposal treatment recycling and recovery of this product please contact Prochem Europe Sales Department Telephone 44 0 20 8974 1515 Prochem Europe Ltd EEE Producer Registr...

Страница 5: ...if the warranty is approved but DISTRIBUTORS will be responsible for fitting service labour and related charges including travel if applicable and the cost of returning the machine or parts to Prochem...

Страница 6: ...manufacturer or its service agent During operation a hazard may occur when running the machine over the power supply cord The power supply cord should be regularly inspected for signs of damage If th...

Страница 7: ...ution tank Do not overfill the solution tank AFTER USE flush solution system and rinse the waste tank with clean water and remove loose fibres from the vacuum filter ALWAYS observe directions and safe...

Страница 8: ...chine connected to an electrical outlet when unattended Do not immerse or use this machine in standing water Such use may cause electric shock This equipment is not designed to handle or use combustib...

Страница 9: ...refill with clean hot solution using a separate bucket By using this technique the solution tank is kept topped up and the recovery tank is always below warning level all in one journey The filter in...

Страница 10: ...09 MULTI PRO A concentrated pre spotter and traffic lane cleaner for treating spots stains and heavily soiled traffic areas prior to extraction cleaning Dilute with warm water at 1 4 to 1 8 and apply...

Страница 11: ...ket under the drain elbow and pull up the drain valve T handle Dirty solution will pour out until the tank is empty Close the drain valve Use a clean bucket when you refill the solution tank 5 When th...

Страница 12: ...the base of the skirting board 3 Operate solution trigger to apply spray cleaning solution whilst simultaneously drawing back the wand toward the operator thus allowing the vacuum nozzle to extract th...

Страница 13: ...onductor of the wire coloured blue shall be connected to the terminal marked N and the conductor of the wire coloured green and yellow shall be connected to the terminal marked with the Earth symbol t...

Страница 14: ...f a reduction in operating pressure leakage or pump failure refer to the Fault Finding Guide and contact your Prochem Distributor VACUUM MOTOR CAUTION ONLY QUALIFIED MAINTENANCE PERSONNEL SHOULD ATTEM...

Страница 15: ...Galaxy Manual 1 7 15 Page 15 of 33...

Страница 16: ...Galaxy Manual 1 7 15 Page 16 of 33...

Страница 17: ...Galaxy Manual 1 7 15 Page 17 of 33...

Страница 18: ...Galaxy Manual 1 7 15 Page 18 of 33...

Страница 19: ...Galaxy Manual 1 7 15 Page 19 of 33...

Страница 20: ...Galaxy Manual 1 7 15 Page 20 of 33...

Страница 21: ...Galaxy Manual 1 7 15 Page 21 of 33...

Страница 22: ...Galaxy Manual 1 7 15 Page 22 of 33...

Страница 23: ...116213 00 G90007 1 VACUUM 2 STAGE 5 7 220 240V VACUUM 2 STAGE 5 7 REVERSE FAN 220 240V 1 1 10 J00639 SCREW CLAMP 1 63 X 2 43 1 11 E00618 J00618 VAC HOSE 2 GREY WIRE 1 12 E11969 F11969 HANDLE 1 13 E118...

Страница 24: ...E11692 D11692 LATCH 2 33 E11529 C11529 SCREW 10 32 X 0 375 4 34 E12013 C12013 SCREW 3 8 16 X 1 5SS 2 35 D12121 LATCH BUTTON BLACK 2 36 C00254 LOCK WASHER 2 37 E02294 C02294 SCREW 20 X 1 25 SS 2 38 D00...

Страница 25: ...CREEN c w K11965 ELBOW 1 7 E00919 K00672 PVC PIPE 1 5 X 6 75 SCH 40 WHT 1 8 E11961 K11961 ADAPTOR PVC 1 5 1 9 E00665 1 K00665 1 HOSE ADAPTOR 1 5 BLACK 2 9A BS5201 FALL OUT TUBE AND ELBOW NOT SHOWN 1 1...

Страница 26: ...CORE 13A 220 240V 1 11 E02211 1 B02211 1 SWITCH ROCKER GREEN LIGHT 2 12 E02576 H02576 LABEL VACUUM 1 13 E02574 H02574 LABEL PUMP 1 14 E02714 K02714 PLUG 0 5 1 15 E00565 13 H00565 13 LABEL SERIAL NUMBE...

Страница 27: ...A00053 45 DEG ELBOW 0 25MP X 0 25FP 1 33 C00284 SCREW 10 32 X 0 375 EARTH 1 34 E00095 1 A00168 18 BUSHING 0 25M X 0 125F 1 35 E11876 11876 2A 0 125 HIGH PRESSURE HOSE ASSY 2FT 1 PF00616 G VAC38ZC VACU...

Страница 28: ...Galaxy Manual 1 7 15 Page 28 of 33 AC1030 WAND PARTS LIST...

Страница 29: ...LHA DIAPHRAGM AND DRIVE BEARING ASSY 1 5 MOTOR 230V AC 1 6 E11764EBK G11764 1 EBK CARBON BRUSH KIT 1 REF STOCK CODE PART NO DESCRIPTION QTY 1 E11162 G11162 150PSI PUMP HEAD PLEASE REQUEST WHEN PURCHAS...

Страница 30: ...Galaxy Manual 1 7 15 Page 30 of 33 PM2501 HAND TOOL PARTS LIST...

Страница 31: ...Galaxy Manual 1 7 15 Page 31 of 33 AC1039 HAND TOOL PARTS LIST...

Страница 32: ...Galaxy Manual 1 7 15 Page 32 of 33 WIRING DIAGRAM MODEL AX500 220 240V 50Hz...

Страница 33: ...60335 1 BS EN 60335 2 68 EN 55014 1 EN 55014 2 BS EN 61000 3 2 BS EN 61000 3 3 BS EN 50366 And comply with the requirements of as amended 2006 95 EC Low Voltage LVD Directive 2004 108 EC Electromagnet...