GALA ELECTRONICS 221ACDC
GALA ELECTRONICS 221ACDC
GALA ELECTRONICS 221ACDC
GALA ELECTRONICS 221ACDC
E
E
E
E
GB
GB
GB
GB
0
45
11.3
AC TIG WELDING
S5
Use this button to select one of the following welding modes:
AC TIG PULSED AC TIG
S4
Use this button to select one of the following torch trigger procedures:
2 STEP 2T SPOT 4 STEP 4 STEP BI-LEVEL
11.3.1
AC TIG PARAMETERS SETTING (1ST LEVEL)
S3
Press this button to scroll the list of settings to edit.
The selected parameter and its value are shown on the following displays: D2
E1
Using the encoder, edit the value of the selected setting.
The value is saved automatically.
Press any key (except S3) to save the setting and quit the menu.
Tab. 9 - 1st level menu parameters in AC TIG mode
PARAMETER
MIN
DEFAULT
MAX
WELDING CURRENT
5 A
80 A
220 A
MAX WELDING CURRENT
5 A
80 A
220 A
SECOND CURRENT BI-LEVEL
10 %
50 %
200 %
*1
BASE CURRENT
1 %
40 %
200 %
SYN
SYN
SYN
*3
PEAK TIME
0.1 s
5.0 s
5.0 s
*5
1 %
50 %
99 %
*4
SYN
SYN
SYN
*3
BASE TIME
0.1 s
5.0 s
5.0 s
*5
PULSE FREQUENCY
0.1 Hz
100 Hz
1.0 kHz
*4
0.1 Hz
5.0 Hz
5.0 Hz
*5
SYN
SYN
SYN
*3
SLOPE DOWN
0.0 s
0.0 s
25.0 s
FINAL CURRENT
5 %
5 %
80 %
*2
5 A
5 A
220 A
*2
POST-GAS
0.0 s
10.0 s
25.0 s
PRE-GAS
0.0 s
0.1 s
10.0 s
START CURRENT
2 %
50 %
200 %
5 A
40 A
220 A
SLOPE UP
0.0 s
0.0 s
25.0 s
*1: This parameter is set as a percentage referred to the value of the following parameter: WELDING CURRENT
*2: The value of this parameter can be set as a percentage of the welding current or as an absolute value expressed in Amperes.
*3: SYN: This code indicates that parameters control is synergic. The optimal value of this parameter is set automatically by the microprocessor
on the basis of the preset welding current value. This value can be displayed but it is not user-adjustable.
*4: Available when "KIND OF PULSE" parameter= FAST
*5: Available when "KIND OF PULSE" parameter= SLOW
11.3.2
AC TIG PARAMETERS SETTING (2ND LEVEL)
S3
Access the 2nd level menu by holding the button down for 3 seconds.
L.2
The message appears on the following displays: D1
L.2= LEVEL.2= 2ND LEVEL MENU
S3
Press this button to scroll the list of settings to edit.
The selected parameter and its value are shown on the following displays: D2
E1
Using the encoder, edit the value of the selected setting.
The value is saved automatically.
Press any key (except S3) to save the setting and quit the menu.