Linc inst v2.1
7
Unit weight empty
185kg
Maximum user weight 26stone (165kg)
Electrical supply 230V -50-60Hz – refer to label
Switched fuse spur rated 5 Amp
RCCB rated 30mA
System operating voltage 24 volt
Typical amp 24v at full load 3 amps
Preparation of Site
(a)
Carefully remove all packaging and inspect bath thoroughly.
Note:
Do not use sharp knives or instruments to remove packaging around the finished surface
areas of the bath.
(b)
Ensure all component parts are present before proceeding to remove any existing facilities.
(c)
Remove any existing equipment and materials as necessary to prepare the site.
(d)
Prepare the floor area and ensure it is flat, level and structurally sound.
(e)
A switched fuse spur rated at 5A, fitted with a RCCB rated at 30mA will also be required.
Electrical Work
All electrical work must comply with current local regulations and should only be carried out by a
qualified electrician.
The electrical supply should be fed via the mains through a RCCB to a switched fused spur rated at 5
Amps where the power cable (supplied with the bath) is hard-wired connected. Please note this must be
accessible by the property owner to allow them to switch the unit off if required (i.e. NOT BEHIND
PANELS OR BOXED IN).
Test the unit is functioning by operating the up and down buttons so that the bath lifts & lowers, and
ensure the green power indicator light is visible on the control box check using a mirror.
Bath Fitting
(a)
Remove the transportation bars & wheels.
It is imperative that the bath is correctly level in all planes, as any distortion will cause
the 4 stainless platform rods to judder & possible leakage through the bath glands.
(b)
Fit bath to the floor using the powered bath installation kit provided – see page14
.
Make sure the floor is sound in the bath fixing area; offer the bath into the required
position.
Mark the fixing center’s for the tap end base plate fig (10) & fit to the floor using the
installation kit provided, making sure the stainless rod’s are vertical in both planes pack
as required to achieve this.
Repeat the same for the opposite end making sure the dimension between the base
plates is 956mm see fig (11)
& making sure the stainless rod’s are vertical in both
planes pack as required to achieve this
Plumbing
Water & waste Connection are situated at the tap end of the unit there are 2 x 22mm tail
Pipes for the hot supply marked red & cold supply marked blue.