background image

                                                         

 

 

 

12

 / 

12

 

*checkoff* / *check*0* 

End check function 

Deep Sleep Setting 

*sleep*1-99* 

1-99  represents  hours  of  deep  sleep 
period. 

* sleepoff* 

End Deep Sleep function. 

GeoFence Setting 

*fence*1-99* 

1-99 

represents 

01-99km 

radius 

“bubble” around the device. 

*fenceoff* 

End Geofence function 

Status query 

*status* 

Check system status 

Multi Controller 

*multiquery* 

Enable multi controller function 

*multiqueryoff* 

End multi controller function 

Device Information 

*about* 

Software 

edition 

information 

and 

device’s serial number. 

 

Содержание GT3012

Страница 1: ...1 12 Magnetic Portable GPS tracker with Installation in Seconds GT3012...

Страница 2: ...THE MASTER CONTROLLER 6 6 3 EMERGENCY TAKEOVER FUNCTION 7 6 4 CHANGING THE PASSWORD 7 7 MOTION DETECTED ALERT 7 7 1 VIBRATION SENSITIVITY 7 7 2 SMS OR CALL ALERT SETTINGS 7 8 SMS LOCATION QUERY 8 8 1...

Страница 3: ...3 12 16 COMMAND SETTING LIST 11...

Страница 4: ...0mAh rechargeable Lithium Ion battery can wait for a month in a true sleeping standby for motion or vibration to wake it into pre programmed periodic location reporting when it starts moving Key Featu...

Страница 5: ...s must be less than 3 seconds each in all uses This control button is at the middle top of the device a On Press power button 5 times Both blue and green indicating light will be on for 30 seconds b O...

Страница 6: ...ur master controller no is 55 12345678910 Then your login account would be 005512345678910 Default Password 123456 6 Operation Commands Guide 6 1 Set APN VERY IMPORTANT AND MUST BE DONE 1ST For the de...

Страница 7: ...stem Since certain applications are more sensitive to external vibration sources the sensor has variable sensitivity settings The unit comes from the factory pre set to 1 on a scale of 1 5 with 1 bein...

Страница 8: ...ion through cell phone browser It is suitable for smart phone user only Note Device will start positioning once it is powered on location data will be saved and retained in memory every minute automat...

Страница 9: ...ck of 30 60 by controlling sampling frequency and data upload interval The device can be set to collect location data regularly and uploaded to server at appointed interval Initiate the start of inter...

Страница 10: ...t exits the geofence will be immediately texted to the master controller as a GeoFence Exit Alert 11 2 Disable the Geofence SMS fenceoff Device Response The Geofence is disabled It should be noted tha...

Страница 11: ...efault setting is 1 Alert Setting callalert Call alert will call master number 2 times when motion is detected after 3 minutes non movement smsalert SMS notification will sent to master number when mo...

Страница 12: ...ion GeoFence Setting fence 1 99 1 99 represents 01 99km radius bubble around the device fenceoff End Geofence function Status query status Check system status Multi Controller multiquery Enable multi...