Specifications

FCC Registration Number ..................................................................................... ADG9ZP-16816-VH-E

Ringer Equivalency (REN) ................................................................................................................ 0.4B

Telephone Network Interface..................Telephone Central Office Line or PBX Line, (USOC) RJ11 jack,

using 2-wire loop start (bridged ringing) circuit

Power input ............................................. 105-130/210-260 V ac, 50-60 Hz, or 23-28 V dc, 30 watts max.

Network signaling .......................................................................................................................... DTMF

Controls .........................................................................Access, Reset, and Day/Night front panel switch;

page line, party line, and sidetone level controls inside enclosure

Material/finish .................................................................... High-impact, glass-reinforced polyester, gray;

internal circuitry surrounded by metal shields

Mounting......................................................................... Wall or column, four 0.280-inch mounting holes

Connections..................  4 drill spots for locating conduit; entrance to internal terminal block connections;

14-foot cable with USOC RJ11C-type modular jack for telephone subset

Dimensions .................................................................  9.5 H 

×

 8 W 

×

 3.8 D inches; (241 

×

 201 

×

 97 mm)

Temperature range...............................................................................  0º C to +70º C (+32º F to +158º F)

Environmental rating ................................................. NEMA-12 dust-tight and drip-tight indoor enclosure

Weight ..............................................................................................................................  9 lbs. (4.08 kg)

Page/Party

®

 Interface

Page line.................................................... 33 ohm nominal load impedance (from line balance assembly)

Party line....................................................  33 ohm nominal ac source impedance (internal line balanced)

Output level...................................................................................................Adjustable; 1.5 V

RMS

 nominal

Replacement Parts

Part Number

Description

12513-003

Hinge Replacement Kit/Internal Plugs

12516-001

Screw Pack, Phillips 1/8 inch (10 pack)

61007-002

Cable Assembly, 4-conductor, 14 foot

69101-001

PCBA, Telephone Interface Power Supply/Termination Board

69111-001

PCBA, Programmable Telephone Interface Board

69112-001

PCBA, Programmable Telephone Interface LED Switch Board

Содержание TI984

Страница 1: ...Telephone Line Connections 4 Power 4 Page Party Connections 5 Remote Connections 5 Programming General Instructions 6 Programming Procedure 7 Entering and Exiting the Programming Mode 7 Selecting an I...

Страница 2: ...n system may vary from the day shift to the night shift this interface can be configured for two independent sets of operating parameters day mode and night mode For example the method used to receive...

Страница 3: ...ear both the GAI Tronics Page Party system and the RJ11C receptacle from the telephone company or Private Branch Exchange PBX The distance from the TI984 to one Page Party station should be such that...

Страница 4: ...ssembly other than the recommended size it is the installer s responsibility to provide the proper earth ground bonding Hub s must be connected to the conduit before being connected to the enclosure T...

Страница 5: ...mmended because it allows the use of all the available types of incoming modes If the call from the CO is to be directly connected to the Page Party system use the bypass feature available on the PBX...

Страница 6: ...of the Page Party system See Figure 5 Party line connections should be made to terminals 13 and 14 as shown in Figure 5 and on the connection diagram printed on the power supply circuit board rear enc...

Страница 7: ...h a set of default parameters listed in the Programming Summary Chart on page 13 Read the entire Programming section record the desired selections in the column titled User Programming and then procee...

Страница 8: ...I984 party line The programmer should then proceed with the programming instructions If the access method has been changed refer to the Selecting an Incoming Access Method section page 8 for details o...

Страница 9: ...nected to the party line The maximum number of seconds the call will be held before it is disconnected if not answered 0 to 99 seconds Enabling or disabling the auto connect mode If the unit is progra...

Страница 10: ...bling the auto connect mode If the unit is programmed to auto connect the caller will be directly connected to the designated party line if that line is already off hook Access codes the two digit cod...

Страница 11: ...after the fifth ring Hang up Delay This parameter sets the time that the TI984 pauses between the time when the Page Party station goes on hook and the call is disconnected If the delay is set to 0 th...

Страница 12: ...lly transferred to the designated party line provided a station is off hook on the designated party line Function SELECT INCOMING CALL VOICE ACCESS METHOD KEY SEQUENCE 3 0 P P M M A DESCRIPTION If sel...

Страница 13: ...ethod at 5 enter the following code 3 2 1 5 2 5 1 2 5 Function SET NUMBER OF INCOMING RINGS KEY SEQUENCE 4 N DESCRIPTION Sets the number of rings that must elapse before the TI984 acknowledges an inco...

Страница 14: ...ne to the receiver To complete this adjustment blow into the microphone at the station while adjusting the potentiometer on the TI984 for minimum signal in the ear piece of the station As the potentio...

Страница 15: ...oles Connections 4 drill spots for locating conduit entrance to internal terminal block connections 14 foot cable with USOC RJ11C type modular jack for telephone subset Dimensions 9 5 H 8 W 3 8 D inch...

Страница 16: ...be Buyer s sole and exclusive remedy and in no event shall GAI Tronics warranty obligations with respect to services exceed 100 of the total cost of services provided hereunder Warranty Periods Every...

Отзывы: