GAI-Tronics RigCom 400-001 Скачать руководство пользователя страница 16

Pub. 42004-376D 

Models 400-001 and 400-002NS RigCom Stations 

Page 14 of 20 

P:\Standard IOMs - Current Release\42004 Instr. Manuals\42004-376D.docx 
09/18 

F1/F2 Fuses 

WARNING

 

—Do not remove fuses when energized.   

Replace with the same type and size fuse for continued safe operation. 

F1 is the fuse on the ac power line:  0.5 A, SLO-BLO, 250 V, 5×20 mm, UL. 

F2 is the fuse on the dc power line:  2.0 A, SLO-BLO, 250 V, 5×20 mm, UL. 

Inspect and clean the machined flange flame joint surfaces of both the cover and box.  Surfaces must be 
smooth, free of nicks, scratches, dirt, or any foreign particle build-up that would prevent a proper seal.  
Surfaces must seat fully against each other to provide a proper explosion-proof joint.  Clean surfaces by 
wiping with a clean lint-free cloth. 

Install and tighten all cover bolts to 17 ft∙lb, (23 N∙m).  Make certain no cover bolts are omitted.  Use only 
the bolts supplied with the enclosure. 

Troubleshooting 

Problem 

Solution 

Any problem with station 
performance 

Always review all steps of installation, ensuring that you 
correctly followed 

all

 steps.  Check all terminations on the 

board. 

Speaker volume needs 
adjustment 

 

Adjust volume control. 

 

Replace speaker or driver. 

Crosstalk 

One or more system cable pairs may be improperly terminated.  
Visually inspect the system cable for accidental crossing of 
cable pairs or grounds. 

 

Replacement Parts and Accessories 

Contact GAI-Tronics for replacement part information. 

The following accessories are available for the RigCom stations: 

Part No. 

Description 

12801-001 

auxiliary microphone 

51052-003 

auxiliary footswitch 

10438-001 

microphone I.S. barrier kit (contains 12801-001 auxiliary mic assembly) 

12807-001 

connector kit 

60075-001 

audio cable, No. 18 AWG, (two-pair) 

 

Содержание RigCom 400-001

Страница 1: ...001 Only 3 Mounting 4 Hardware Configuration 5 External 5 Internal 5 Wiring 6 Station Wiring 6 System Line Balance 7 System Wiring 9 Field Installation Interface 9 TB1 Speaker Terminal Block 9 TB2 AC...

Страница 2: ...1212 Fax 610 796 5954 VISIT WWW GAI TRONICS COM FOR PRODUCT LITERATURE AND MANUALS Speaker Model 400 001 Only 15 Station 15 Environmental 15 Approvals 16 Appendix A InterfacingaModel400 001RigComStat...

Страница 3: ...lk or master slave communication system for the following hazardous locations Model 400 001 Class I Div 1 Groups C and D Model 400 002NS Class I Div 1 Groups B C and D when installed in accordance wit...

Страница 4: ...eries of GAI Tronics equipment Important Safety Instructions 1 Read follow and retain instructions All safety and operating instructions should be read and followed before operating the unit Retain in...

Страница 5: ...and washers or washer head bolts WARNING Insure proper grounding to protective earthing Do not disconnect equipment while energized Inspect and clean the machined flange flame joint surfaces of both...

Страница 6: ...ght of the aluminum enclosure See the Specifications section for the weights and dimensions of the unit The enclosure must be securely fastened with 7 16 inch diameter steel mounting bolts located on...

Страница 7: ...LASS I DIV I GROUPS C D WARNING EXPLOSION HAZARD DO NOT DISCONNECT EQUIPMENT UNLESS TO REDUCE THE RISK OF IGNITION OF HAZARDOUS ATMOSPHERES CONDUIT SEALS MUST BE INSTALLED WITHIN 18 INCHES OF ENCLOSUR...

Страница 8: ...the wires to the terminal blocks located on the PCBA within the enclosure see Figure 4 for connection points and descriptions 5 If using the 10438 001 Auxiliary Microphone Assembly Connect the assemb...

Страница 9: ...or assembly is made for easy installation into the customer supplied junction box NOTE Only one line balance resistor assembly is needed per system The resistor assembly should be installed in a junct...

Страница 10: ...76D Models 400 001 and 400 002NS RigCom Stations Page 8 of 20 P Standard IOMs Current Release 42004 Instr Manuals 42004 376D docx 09 18 Figure 6 Master Slave System cable wiring greater than 4000 feet...

Страница 11: ...in talk mode the signal level reduces by half see Figure 7 for systems with more than ten stations to determine the maximum line distance Figure 7 Number of Stations vs Line Length Field Installation...

Страница 12: ...ower supply negative terminal No connection when external dc power supply is not used TB4 AudioandLow VoltageControl TerminalBlock The following table lists the connections for the low voltage control...

Страница 13: ...SW1 allows configuration of the unit as a master or slave unit The unit is configured as a master if the switch is in the MASTER position The unit is configured as a slave if the switch is in the SLAV...

Страница 14: ...s The push to talk switch must be held down as long as the operator talks Releasing the switch deactivates the microphone and returns the unit to listen mode Figure 8 Common Talk Wiring Detail Master...

Страница 15: ...ance section unless you are qualified to do so Regular inspection and a good preventive maintenance program will increase the reliability of your GAI Tronics station The GAI Tronics Field Service Depa...

Страница 16: ...th Install and tighten all cover bolts to 17 ft lb 23 N m Make certain no cover bolts are omitted Use only the bolts supplied with the enclosure Troubleshooting Problem Solution Any problem with stati...

Страница 17: ...output Gain Listen mode 17 dB Gain Talk mode speaker as the microphone 42 dB Gain Talk mode auxiliary microphone 48 dB Speaker Model 400 001 Only Rating 30 W maximum Impedance 16 Frequency response 4...

Страница 18: ...400 001 RigCom Station is designed to operate as a field replacement or system addition to the MS39xx RigCom Stations The MS39xx uses an unbalanced system for communication and uses the negative of th...

Страница 19: ...Model 400 001 Stations are designed to operate either in balanced or unbalanced systems An unbalanced system for communication uses the negative of the audio pair as the ground reference for the contr...

Страница 20: ...tions Page 18 of 20 P Standard IOMs Current Release 42004 Instr Manuals 42004 376D docx 09 18 Figure 13 Master Slave Unbalanced Configuration with the Model 400 001 as Master Figure 14 Master Slave Un...

Страница 21: ...00 002NS RigCom Stations Page 19 of 20 P Standard IOMs Current Release 42004 Instr Manuals 42004 376D docx 09 18 Figure 15 Unbalanced Common Line Configuration Figure 16 Master Slave Balanced Configur...

Страница 22: ...400 002NS RigCom Stations Page 20 of 20 P Standard IOMs Current Release 42004 Instr Manuals 42004 376D docx 09 18 Figure 17 Master Slave Balanced Configuration with Model 400 001 as Slave Figure 18 B...

Страница 23: ...of the Contractor s personnel from the work site Re performance of services shall be Buyer s sole and exclusive remedy and in no event shall GAI Tronics warranty obligations with respect to services e...

Отзывы: