P
UB
.
42004-461D
H
ANDS
-
FREE
V
O
IP
R
ETRO
-F
IT
T
ELEPHONES
P
AGE
19 of 23
f:\standard ioms - current release\42004 instr. manuals\42004-461d.doc
02/15
Status Indication
Power
The Power LED located on the VoIP PCBA illuminates when power is applied to the telephone. Refer to
Figure 9 on page 15 for location.
Heartbeat
The Heartbeat LED located on the VoIP PCBA will flash once communication over the LAN is
established. Refer to Figure 9 on page 15 for location.
EACT
The EACT LED located on the VoIP PCBA will turn ON when VoIP PCBA is connected to an Ethernet
device and flash when data is being transmitted. Refer to Figure 9 on page 15 for location.
Programming
The installer should ensure that the network is configured to allow VoIP communications (using the SIP
protocol) between the desired locations before attempting to configure the GAI-Tronics VoIP Telephones.
The general sequence for set up of the VoIP telephone is as follows:
VoIP PCBA Setup
The easiest way to get started is to make a network connection to the unit and log on via a web browser.
The unit is initially set with a static IP address:
IP address
192.168.1.2
A user name and password will be requested. The initial factory settings are:
User Name
user
Password
password
Changing the user name and password is recommended. This security measure helps to prevent
unauthorized changes to the VoIP Telephone Interface’s configuration.
VoIP PCBA Initial Network Configuration
Each VoIP PCBA must be set up for the network prior to installation. Assign a local ID, domain, proxy,
and registrar.
Assign a host name
The host name provides identification of the different VoIP PCBAs on the
network.
Test
Verify that calls can be made successfully.
Maintain
Monitor alarms. Set up auto-updates.