Wiring
Pressure-type terminal blocks are provided inside the LE300 for connecting the incoming field wiring.
The terminal blocks can support a wire size of No. 24 AWG to No. 12 AWG. It is recommended that the
installer crimp ferrules on the end of each wire before attaching the wire into the terminal block to ensure a
reliable termination. Wiring connections to the LE300 are described below.
Power Connections
Connect input power of 120/240 V ac at 50/60 Hz to the double-pole circuit breaker. Connect the ground
wire to the ground bar.
Page/Party
®
System Cable Connection
Connect the audio conductors (page line and party line one through five) of the Page/Party
®
system cable
to either P5 or P8 on the audio termination board. Each connection point is labeled next to the terminal
block as shown below.
Figure 14. Page/Party
®
Cable Terminals