Rules for Interconnecting More than Two Model LE300s
When connecting more than two Model LE300s together, these rules must be followed.
A maximum of two Model LE300 pairs can be connected in series when the series connections are
made using Page/Party
®
cable as shown below.
Figure 11. Maximum Series Connections
When Model LE300s are connected in series, a problem can arise when training the echo cancellation.
If more than one Model LE300 is training echo cancellation on a signal line at the same time, then
none of them will train echo cancellation properly. To prevent this, power each Line Extender one at a
time. Wait for the echo cancellation to complete on the first Line Extender before powering the
second.
A maximum of eight pairs of Model LE300s can be connected in parallel. Parallel connections must
be made using the LVDS link and the T1/E1 link as shown below.
Figure 12. Maximum Parallel Connections