GAI-Tronics Elemec3 013-02-0095-002 Скачать руководство пользователя страница 2

Pub. 42004-480B 

Model 013-02-0095-002 

Elemec3

 System Controller 

Page 2 of 11 

e:\standard ioms - current release\42004 instr. manuals\42004-480b.doc 
05/14 

The system provides two internal audio paths to enable simultaneous broadcast of audio to distinct output 
zones.  For ease of installation and maintenance all cabinet internal connections are on a plug/socket 
basis. 

The software control is designed to be as flexible as possible, and can easily be configured via the TCP/IP 
network connection on the rear of the 

Elemec3

 System Controller using the 

Elemec3

 Console software 

application.  Hot standby amplifier control is provided so that a powered spare amplifier(s) is 
automatically connected to the loudspeaker network of the failed amplifier(s). 

PABX access and Page/Party

®

 access are configured so that telephone/intercom inputs can be digitally 

stored and replayed to completely eliminate the possibility of acoustic feedback between telephone/ 
intercom and local loudspeaker. 

Up to 256 individually programmed relay outputs and 256 input contact points are available through the 
LAN interface on the rear of the 

Elemec3

 System Controller.  Duplicate 

Elemec3

 System Controller can 

be used for additional redundancy.  System status, including current audio activity, faults, input, output 
and amplifier states, are monitored via the TCP/IP network connection using the 

Elemec3

 Portal software 

application. 

The 

Elemec3

 System Controller is exclusively designed for use in an 

Elemec3

 system and is not intended 

for use with other types of equipment. 

Important Safety Instructions 

1. Read these instructions.

2. Keep these instructions.

3. Heed all warnings.

4. Follow all instructions.

5. Do not use this apparatus near water.

6. Clean only with dry cloth.

7. Do not block any ventilation openings.  Install in accordance with the manufacturer’s instructions.

8. Do not defeat the safety purpose of the polarized or grounding-type plug.  A polarized plug has two

blades with one wider than the other.  A grounding type plug has two blades and a third grounding
prong.  The wide blade or the third prong is provided for your safety.  If the provided plug does not fit
into your outlet, consult an electrician for replacement of the obsolete outlet.

Содержание Elemec3 013-02-0095-002

Страница 1: ...ation of your GAI Tronics product or system This manual may not be disclosed in any form in whole or in part directly or indirectly to any third party General Information The Model 013 02 0095 002 Ele...

Страница 2: ...ed relay outputs and 256 input contact points are available through the LAN interface on the rear of the Elemec3 System Controller Duplicate Elemec3 System Controller can be used for additional redund...

Страница 3: ...required when the apparatus has been damaged in any way such as power supply cord or plug is damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to...

Страница 4: ...4 of 11 e standard ioms current release 42004 instr manuals 42004 480b doc 05 14 Rear Panel Connections Refer to Figure 3 System connections are made to the rear of the Elemec3 System Controller US C...

Страница 5: ...ntroller Internal Components Component Description Digital PCBA Central processing unit and digital communications Analog PCBA Provides speech recording and play back to eliminate feedback Telephone I...

Страница 6: ...rack It requires 1U 1 75 inches of height Duplicate System In a duplicated or redundant system two Elemec3 System Controllers designated as A and B are located in system racks at different location In...

Страница 7: ...EDs operate in accordance with the following table Table 2 Front Panel LED Indications LED Indication PA IN USE Green Indicates the PA system is in use Off Not in use SYSTEM STATUS Green Normal operat...

Страница 8: ...fications via the LAN connection on the rear panel PABX connection The interface to the telephone system is made via the PABX connector on the rear panel API 1 API 4 Access panel interface connections...

Страница 9: ...terface cards T500 mA F8 Input Output Cards T1 6 A F1 Auxiliary Power Output T2 5 A Power to access panels is fused to 100 mA on Access Panel Interface cards Access Panel Interfaces Access panels per...

Страница 10: ...eed 57 6 kbps A B Interlinks Audio Input Operating level 2 2 Vpp maximum at 1 kHz Input impedance 60 k ohms at 1 kHz 3 dB bandwidth 200 Hz 20 kHz input to zone output Data Link Type RS 485 fully duple...

Страница 11: ...nhibit Status LEDs Unit Power PA In Use System Status Status Monitor Elemec3 Portal Ports Ethernet Port RJ45 Connector USB Device Port Front Type A USB Device Port Rear Type A O C Voltage 5 1 V dc nom...

Страница 12: ...of the Contractor s personnel from the work site Re performance of services shall be Buyer s sole and exclusive remedy and in no event shall GAI Tronics warranty obligations with respect to services e...

Отзывы: