Event Audio Outputs 

Audio Output 

Output Level ................................................................  2.2 Vpp maximum at 1 kHz into 600-ohm load 
3-dB bandwidth ...........................................................................................................  200 Hz–20 kHz 
Key switch...............................................................................................................  Auto alarm inhibit 

Status LEDs ............................................................................................................................   Unit  Power 
 

PA In Use 

 

System Status 

Status Monitor ..................................................................................................................  

Elemec3

 Portal 

Ports 

Ethernet Port ...............................................................................................................  RJ45 Connector 
USB Device Port - Front ........................................................................................................... Type A 
USB Device Port - Rear ............................................................................................................ Type A 

O/C Voltage ...................................................................................................................  5.1 V dc nominal 
Current  .......................................................................................  500 mA (maximum) +/

10 mA per port 

Memory card type .........................................................................................................  SD Memory Card 

Environmental 

Operating temperature range ..............................................................................................  20

C to +50

Relative humidity ..............................................................................................................................   95% 

Mechanical 

Unit dimensions ..........................................  482.6 W 

 43.7 H 

 226.3 D mm (19.0 

 1.72 

 8.91 inches) 

Unit weight ......................................................................................................................  2.4 kg (5.2 lbs.) 

Approval 

CE Mark 
NRTL ................................................................................................................................ UL/CSA  60065 

Содержание Elemec3 013-02-0095-002

Страница 1: ...ation of your GAI Tronics product or system This manual may not be disclosed in any form in whole or in part directly or indirectly to any third party General Information The Model 013 02 0095 002 Ele...

Страница 2: ...ed relay outputs and 256 input contact points are available through the LAN interface on the rear of the Elemec3 System Controller Duplicate Elemec3 System Controller can be used for additional redund...

Страница 3: ...required when the apparatus has been damaged in any way such as power supply cord or plug is damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to...

Страница 4: ...4 of 11 e standard ioms current release 42004 instr manuals 42004 480b doc 05 14 Rear Panel Connections Refer to Figure 3 System connections are made to the rear of the Elemec3 System Controller US C...

Страница 5: ...ntroller Internal Components Component Description Digital PCBA Central processing unit and digital communications Analog PCBA Provides speech recording and play back to eliminate feedback Telephone I...

Страница 6: ...rack It requires 1U 1 75 inches of height Duplicate System In a duplicated or redundant system two Elemec3 System Controllers designated as A and B are located in system racks at different location In...

Страница 7: ...EDs operate in accordance with the following table Table 2 Front Panel LED Indications LED Indication PA IN USE Green Indicates the PA system is in use Off Not in use SYSTEM STATUS Green Normal operat...

Страница 8: ...fications via the LAN connection on the rear panel PABX connection The interface to the telephone system is made via the PABX connector on the rear panel API 1 API 4 Access panel interface connections...

Страница 9: ...terface cards T500 mA F8 Input Output Cards T1 6 A F1 Auxiliary Power Output T2 5 A Power to access panels is fused to 100 mA on Access Panel Interface cards Access Panel Interfaces Access panels per...

Страница 10: ...eed 57 6 kbps A B Interlinks Audio Input Operating level 2 2 Vpp maximum at 1 kHz Input impedance 60 k ohms at 1 kHz 3 dB bandwidth 200 Hz 20 kHz input to zone output Data Link Type RS 485 fully duple...

Страница 11: ...nhibit Status LEDs Unit Power PA In Use System Status Status Monitor Elemec3 Portal Ports Ethernet Port RJ45 Connector USB Device Port Front Type A USB Device Port Rear Type A O C Voltage 5 1 V dc nom...

Страница 12: ...of the Contractor s personnel from the work site Re performance of services shall be Buyer s sole and exclusive remedy and in no event shall GAI Tronics warranty obligations with respect to services e...

Отзывы: