Pub. 42004-525A
Model 370-901 SP2 to Page/Party
®
Bridge
Page 7 of 16
P:\Standard IOMs - Current Release\42004 Instr. Manuals\42004-525A.docx
08/18
Mute Connection—P5
The muting conductor of the Page/Party
®
system cable has no function in the SP2 to Page/Party
®
Bridge.
Terminal block
P5
provides a dead ended termination for the muting conductor of the Page/Party
®
system
cable (see Figure 4):
1.
Install a ferrule onto the end of the orange wire.
2.
Connect the wire to pin one on pluggable terminal block
P5
.
3.
Connect the pluggable terminal block to terminal block
P5
.
Power—P1
The SP2/Page/Party
®
Bridge operates from a 120/230 V
ac, 50/60 Hz power source. AC power is connected at
terminal block
P1
:
1.
Pull the cable from the power source into the
enclosure.
2.
Install ferrules onto the wire ends.
3.
Connect the line, and neutral, conductors to the
pluggable terminal block (see Figure 4 and Table 6).
4.
Connect the pluggable terminal block to terminal
block
P1
Close the Enclosure
1.
Reconnect the front cover to the rear enclosure by pushing the hinge pins on the front cover into the
holes on the left side of the rear enclosure until a click is heard.
2.
Rotate the front cover to close the enclosure.
3.
Install and tighten the four screws on the front cover.
Configuration
SP2 to Page/Party
®
Bridges are configured using the GUDA (GAI-TRONICS Universal Device
Application) software. Install the GUDA software and run it to configure Page/Party
®
bridges as follows:
1.
Launch the GUDA application by double clicking the GAI-TRONICS Universal Device Application
shortcut from the start menu.
2.
Choose the network interface to perform the discovery.
Table 6. AC Power—P1
Pin
Label
Description
P1-1
LINE
ac hot
P1-2
no connection
P1-3
NEUTRAL
neutral