background image

P

UB

. 42004-377C

GAI-Tronics Corporation  P.O. Box 1060, Reading, PA  19607-1060  USA

610-777-1374  

„

  800-492-1212  

„

  Fax:  610-796-5954

V

ISIT WWW

.

GAI

-

TRONICS

.

COM FOR PRODUCT LITERATURE AND MANUALS

Model 293-103, 297-103, 298-103, 293-103AL,

and 294-103AL Externally Powered S.M.A.R.T.

Emergency Phones

Getting Started

Product Overview

Thank you for your purchase of a GAI-Tronics S.M.A.R.T., ADA-compliant, emergency telephone.  In
addition to providing standard emergency telephone operation, GAI-Tronics Self-Monitoring and
Reporting Telephones (S.M.A.R.T.) incorporate leading-edge technology to provide optimum
performance and flexibility.  For example, when used with the GAI-Tronics Telephone Management
Application (TMA) the health of each telephone is monitored and reported.  For complete details, please
refer to the on-line help included with TMA.

The following S.M.A.R.T. emergency telephone models are described in this manual:

Model

Description

293-103

Surface-mount, glass-reinforced polyester enclosure including an emergency push button,
Braille tag, and visual call received indicator.

293-103AL

Surface-mount, aluminum enclosure including an emergency push button, Braille tag, and
visual call received indicator.

294-103AL

Surface-mount, aluminum enclosure including an emergency push button, call push button,
standard telephone keypad, Braille tag, and visual call received indicator.

297-103

Flush-mount, stainless steel front panel including an emergency push button, Braille tag,
and visual call received indicator.

298-103

Flush-mount, stainless steel front panel including an emergency push button, call push
button, standard telephone keypad, Braille tag, and visual call received indicator.

All of the S.M.A.R.T. emergency telephones listed above comply with the Americans with Disabilities
Act (ADA).  Each phone includes a Braille tag for vision-impaired individuals to identify the functions of
the telephone and a visual indication for hearing-impaired individuals indicating that an emergency call
has been answered.

The 

C

ALL 

R

ECEIVED 

W

HEN 

L

IT

 LED is the visual call received indicator.  When a call is initiated by

pressing the emergency push button, the LED will initially flash.  When the telephone is answered and
audio is detected, the LED will light steadily.  The LED remains lit until the call is disconnected.

The GAI-Tronics S.M.A.R.T. Phone product line provides the flexibility to address a diverse range of
applications.  A wide variety of functions can be achieved by altering the configuration data stored in the
phone’s non-volatile memory.  These configuration options include:

 

Pre-programmed auto-dial telephone numbers

 

Maximum call duration

 

Answering options

Содержание 293-103

Страница 1: ...n 3 Placing an Emergency Call from a S M A R T Phone All Models 3 Placing a Non Emergency Call Models 294 103AL and 298 103 Only 3 Receiving a Call 3 Disconnecting Calls 3 Installation 4 Safety Guidel...

Страница 2: ...inum enclosure including an emergency push button call push button standard telephone keypad Braille tag and visual call received indicator 297 103 Flush mount stainless steel front panel including an...

Страница 3: ...busy signal or no answer the emergency phone will automatically dial the first backup or roll over number Again in the event an emergency call cannot connect to first backup telephone number the emerg...

Страница 4: ...ngaNon EmergencyCall Models294 103ALand298 103Only To place a non emergency call 1 Press the CALL push button 2 Wait for dial tone 3 Use the keypad to dial the desired number 4 At the end of the conve...

Страница 5: ...ble within five feet of the telephone the included power supply can be used The ac source and power supply must be mounted in a dry location such as a GAI Tronics stanchion If the ac source is located...

Страница 6: ...s strongly recommended Insert a conduit fitting in the access hole Refer to conduit installation details on page 4 NOTE Use silicone sealant or equivalent around and inside all conduit entries 5 Pull...

Страница 7: ...S M A R T EXTERNALLY POWERED ADA COMPLIANT EMERGENCY PHONES PAGE 6 of 18 d standard ioms current release 42004 instr manuals 42004 377c doc 08 06 Figure 3 Model 293 103 293 103AL and 294 103AL Compon...

Страница 8: ...in the back box and pull the telephone line and power supply cord through 4 Connect the power supply 4 pin connector to the P17 header jack on the PCBA 5 Connect the telephone s modular plug to a USO...

Страница 9: ...r mounting the Model 297 103 and 298 103 S M A R T Emergency Telephones in GAI Tronics Model 236 Series Surface Mount Enclosure and Model 234 234WM stanchions please refer to the installation bulletin...

Страница 10: ...he caller is not TMA then the phone connects in a normal 2 way voice call At the start of this voice call the phone alerts the caller and the called party with two sets of three beep tones Enable Inse...

Страница 11: ...s for the speaker and microphone Both the speaker and microphone adjustments are made using potentiometers on the emergency phone PCBA R106 is the speaker volume adjustment and R88 is the microphone s...

Страница 12: ...olated solid state output capable of switching a maximum of 48 V dc 125 mA or 28 VRMS ac 80RMS mA TB2 OUT1 on the emergency phone PCBA provides the connections for the auxiliary output Refer to Figure...

Страница 13: ...anged we recommend writing down the key sequence from the Command column of Table R 1 Basic Programming Commands Having the programming information written down allows you to enter the key sequence at...

Страница 14: ...MA with the Number of Call In Retries setting Use the 1 command to program these three auto dial numbers The three auto dial telephone numbers are labeled as 11 primary 12 first roll over and 13 secon...

Страница 15: ...tor Example To determine what to enter for the call timeout duration multiply the desired time limit in minutes by 120 For example to determine the call duration entry for a call timeout of five 5 min...

Страница 16: ...icted through the use of the maintenance access PIN The maintenance access PIN should be distributed only to trained maintenance personnel If your S M A R T Phone requires service contact your GAI Tro...

Страница 17: ...emperature range 20 C to 60 C Relative humidity to 95 no condensation PCBA printed circuit board assembly Conformal coated Model 293 103 Enclosure construction Valox high impact glass reinforced polye...

Страница 18: ...nformation Canada IC Certification Number 882B AUXSMART Ringer Equivalence Number 0 2A Connection Method CA11A Replacement Parts Part No Description 293 103 293AL 103 294AL 103 297 103 298 103 233 001...

Страница 19: ...nnect the equipment Users should ensure for their own protection that the electrical ground connections of the power utility telephone lines and internal metallic water pipe system if present are conn...

Страница 20: ...be Buyer s sole and exclusive remedy and in no event shall GAI Tronics warranty obligations with respect to services exceed 100 of the total cost of services provided hereunder Warranty Periods Every...