Call Timeout

The call timeout feature is used to limit the maximum duration of a call.  The call timeout can be any
duration between one minute and 4 ½ hours.  The duration is set in ½ second increments and the valid
range is from 120 to 32,400.  To determine the value associated with a specific time duration, see the
example below.

*37

Data transfer command

<120~32400>

Call duration (120 to 32400 ½ seconds) – See example below.

#

End of string indicator

Example:

To determine what to enter for the call timeout duration, multiply the desired time limit, in minutes, by
120.  For example, to determine the call duration entry for a call timeout of five (5) minutes, do the
following:

5 minutes 

×

 120 = 

600

To enter a call timeout duration of five (5) minutes, enter the character string 

*37600#.

When the call timeout duration has been successfully entered, the phone returns a system-generated
DTMF check-digit.

Table R-1.  Basic Programming Commands

Command:

Factory
Default:

Description:

*1

NN 

<

CHARAC

>#

N/A

Write Memory NN (11-13) with characters (up to 24)

*37<120~32400>#

840

Write Call Timeout (120-32400 

×

 ½ sec).

Factory default is 840, or 7 minutes.

*821

N/A

Turn on the relay output (OUT1)

*921

N/A

Turn off the relay output (OUT1)

*99

N/A

End programming call.  The S.M.A.R.T. phone hangs up.

Содержание 293-103

Страница 1: ...n 3 Placing an Emergency Call from a S M A R T Phone All Models 3 Placing a Non Emergency Call Models 294 103AL and 298 103 Only 3 Receiving a Call 3 Disconnecting Calls 3 Installation 4 Safety Guidel...

Страница 2: ...inum enclosure including an emergency push button call push button standard telephone keypad Braille tag and visual call received indicator 297 103 Flush mount stainless steel front panel including an...

Страница 3: ...busy signal or no answer the emergency phone will automatically dial the first backup or roll over number Again in the event an emergency call cannot connect to first backup telephone number the emerg...

Страница 4: ...ngaNon EmergencyCall Models294 103ALand298 103Only To place a non emergency call 1 Press the CALL push button 2 Wait for dial tone 3 Use the keypad to dial the desired number 4 At the end of the conve...

Страница 5: ...ble within five feet of the telephone the included power supply can be used The ac source and power supply must be mounted in a dry location such as a GAI Tronics stanchion If the ac source is located...

Страница 6: ...s strongly recommended Insert a conduit fitting in the access hole Refer to conduit installation details on page 4 NOTE Use silicone sealant or equivalent around and inside all conduit entries 5 Pull...

Страница 7: ...S M A R T EXTERNALLY POWERED ADA COMPLIANT EMERGENCY PHONES PAGE 6 of 18 d standard ioms current release 42004 instr manuals 42004 377c doc 08 06 Figure 3 Model 293 103 293 103AL and 294 103AL Compon...

Страница 8: ...in the back box and pull the telephone line and power supply cord through 4 Connect the power supply 4 pin connector to the P17 header jack on the PCBA 5 Connect the telephone s modular plug to a USO...

Страница 9: ...r mounting the Model 297 103 and 298 103 S M A R T Emergency Telephones in GAI Tronics Model 236 Series Surface Mount Enclosure and Model 234 234WM stanchions please refer to the installation bulletin...

Страница 10: ...he caller is not TMA then the phone connects in a normal 2 way voice call At the start of this voice call the phone alerts the caller and the called party with two sets of three beep tones Enable Inse...

Страница 11: ...s for the speaker and microphone Both the speaker and microphone adjustments are made using potentiometers on the emergency phone PCBA R106 is the speaker volume adjustment and R88 is the microphone s...

Страница 12: ...olated solid state output capable of switching a maximum of 48 V dc 125 mA or 28 VRMS ac 80RMS mA TB2 OUT1 on the emergency phone PCBA provides the connections for the auxiliary output Refer to Figure...

Страница 13: ...anged we recommend writing down the key sequence from the Command column of Table R 1 Basic Programming Commands Having the programming information written down allows you to enter the key sequence at...

Страница 14: ...MA with the Number of Call In Retries setting Use the 1 command to program these three auto dial numbers The three auto dial telephone numbers are labeled as 11 primary 12 first roll over and 13 secon...

Страница 15: ...tor Example To determine what to enter for the call timeout duration multiply the desired time limit in minutes by 120 For example to determine the call duration entry for a call timeout of five 5 min...

Страница 16: ...icted through the use of the maintenance access PIN The maintenance access PIN should be distributed only to trained maintenance personnel If your S M A R T Phone requires service contact your GAI Tro...

Страница 17: ...emperature range 20 C to 60 C Relative humidity to 95 no condensation PCBA printed circuit board assembly Conformal coated Model 293 103 Enclosure construction Valox high impact glass reinforced polye...

Страница 18: ...nformation Canada IC Certification Number 882B AUXSMART Ringer Equivalence Number 0 2A Connection Method CA11A Replacement Parts Part No Description 293 103 293AL 103 294AL 103 297 103 298 103 233 001...

Страница 19: ...nnect the equipment Users should ensure for their own protection that the electrical ground connections of the power utility telephone lines and internal metallic water pipe system if present are conn...

Страница 20: ...be Buyer s sole and exclusive remedy and in no event shall GAI Tronics warranty obligations with respect to services exceed 100 of the total cost of services provided hereunder Warranty Periods Every...

Отзывы: