background image

(Rev. 10/06)

Warranty

Equipment.

  GAI-Tronics warrants for a period of one (1) year from the date of shipment, that any

GAI-Tronics equipment supplied hereunder shall be free of defects in material and workmanship, shall
comply with the then-current product specifications and product literature, and if applicable, shall be fit
for the purpose specified in the agreed-upon quotation or proposal document.  If (a) Seller’s goods prove
to be defective in workmanship and/or material under normal and proper usage, or unfit for the purpose
specified and agreed upon, and (b) Buyer’s claim is made within the warranty period set forth above,
Buyer may return such goods to GAI-Tronics’ nearest depot repair facility, freight prepaid, at which time
they will be repaired or replaced, at Seller’s option, without charge to Buyer.  Repair or replacement shall
be Buyer’s sole and exclusive remedy.  The warranty period on any repaired or replacement equipment
shall be the greater of the ninety (90) day repair warranty or one (1) year from the date the original
equipment was shipped.  In no event shall GAI-Tronics warranty obligations with respect to equipment
exceed 100% of the total cost of the equipment supplied hereunder.  Buyer may also be entitled to the
manufacturer’s warranty on any third-party goods supplied by GAI-Tronics hereunder.  The applicability
of any such third-party warranty will be determined by GAI-Tronics.

Services.

  Any services GAI-Tronics provides hereunder, whether directly or through subcontractors,

shall be performed in accordance with the standard of care with which such services are normally
provided in the industry.  If the services fail to meet the applicable industry standard, GAI-Tronics will
re-perform such services at no cost to buyer to correct said deficiency to Company's satisfaction provided
any and all issues are identified prior to the demobilization of the Contractor’s personnel from the work
site.  Re-performance of services shall be Buyer’s sole and exclusive remedy, and in no event shall GAI-
Tronics warranty obligations with respect to services exceed 100% of the total cost of the services
provided hereunder.

Warranty Periods.

  Every claim by Buyer alleging a defect in the goods and/or services provided

hereunder shall be deemed waived unless such claim is made in writing within the applicable warranty
periods as set forth above.  Provided, however, that if the defect complained of is latent and not
discoverable within the above warranty periods, every claim arising on account of such latent defect shall
be deemed waived unless it is made in writing within a reasonable time after such latent defect is or
should have been discovered by Buyer.

Limitations / Exclusions.

  The warranties herein shall not apply to, and GAI-Tronics shall not be

responsible for, any damage to the goods or failure of the services supplied hereunder, to the extent
caused by Buyer’s neglect, failure to follow operational and maintenance procedures provided with the
equipment, or the use of technicians not specifically authorized by GAI-Tronics to maintain or service the
equipment.  THE WARRANTIES AND REMEDIES CONTAINED HEREIN ARE IN LIEU OF AND
EXCLUDE ALL OTHER WARRANTIES AND REMEDIES, WHETHER EXPRESS OR IMPLIED BY
OPERATION OF LAW OR OTHERWISE, INCLUDING ANY WARRANTIES OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.

Return Policy

If the equipment requires service, contact your Regional Service Center for a return authorization number
(RA#).  Equipment should be shipped prepaid to GAI-Tronics with a return authorization number and a
purchase order number.  If the equipment is under warranty, repairs or a replacement will be made in
accordance with the warranty policy set forth above.  Please include a written explanation of all defects to
assist our technicians in their troubleshooting efforts.

Call 800-492-1212 (inside the USA) or 610-777-1374 (outside the USA) for help identifying the
Regional Service Center closest to you.

Содержание 263

Страница 1: ...ty General Information GAI Tronics Corporation offers intrinsically safe I S telephones and isolation barrier units IBU which conform to all pertinent requirements in the USA and Canada For convenience a telephone and an IBU can be purchased together under a single model number Model 261 001 for indoor use and Model 271 001 for outdoors However for rack mount configurations or special applications...

Страница 2: ...k is specifically designed for wet locations NEVER touch uninsulated telephone wires or terminals unless the telephone line has been disconnected at the network interface USE CAUTION when installing or modifying telephone lines Install UL Listed telephone line suppressor customer supplied on the telephone line Use silicone sealant or equivalent around and inside all conduit entries Installation of...

Страница 3: ...e cable capacitance level was still within acceptable bounds Cable types with less capacitance have been specified to allow connection distances over one mile For example GAI Tronics Model 60059 001 and 60021 301 cables allow connection distances of up to 1 5 miles Shielded Cable Where multiple I S telephone wires are routed together shielded cable should be used The use of shielded cable prevents...

Страница 4: ...73242 to ensure intrinsic safety 2 Next temporarily connect the I S telephone to the IBU with a short pair of conductors and operate the unit by making a test phone call If any problems are detected see the Troubleshooting section 3 Call the I S telephone from another telephone and adjust the RING PITCH located on the IBU to the desired pitch See Figure 2 for location 4 Disconnect the I S telephon...

Страница 5: ...ub 42004 178D Model 263 Isolation Barrier Unit IBU Page 5 of 13 s_eng gtcproddocs standard ioms current release 42004 instr manuals 42004 178d doc 03 06 Figure 2 Rear of IBU enclosure with cover removed ...

Страница 6: ...closure Install the rear enclosure to a wall of an appropriate surface through the supplied mounting holes 4 Refer to Pub 42004 380 Control Drawing 73242 for wiring details NOTE Telephone system wire must be connected to the Isolation Barrier Unit only and not directly to the I S telephone Battery backup connection is not required for operation of the Model 262 001 and 272 001 I S Phones If batter...

Страница 7: ...ge 7 of 13 s_eng gtcproddocs standard ioms current release 42004 instr manuals 42004 178d doc 03 06 Figure 3 Model 263 Isolation Barrier Unit dimensions Operation The Model 263 Isolation Barrier Unit requires no operator intervention for routine functions ...

Страница 8: ... Non EquipmentRelated Problems Problem Solution The I S phone is inactive with no lights on the IBU when the phone is off hook 1 Check the ac power to the Model 263 IBU 2 Check the ac fuse F4 at the Model 263 IBU 3 Ensure there is no wiring open at the I S phone 1 If the I S phone has a wiring short the IBU lights will be lit in the following pattern O On P Off ISLOOP O LOCK P HOOK P TELCO P 2 If ...

Страница 9: ...short in the connecting cable Cannot dial out but can hear touch tones when pressed 1 Check the Model 263 IBU 2 There is no TELCO connection or it is faulty I S phone appears inactive 1 Check the I S telephone panel 2 Check the ac fuse F4 at the Model 263 IBU 3 Ensure there is no wiring open in the connecting cable or at the I S telephone CAUTION Any field repairs on the intrinsically safe design ...

Страница 10: ... lightning strike To ensure safe operation protective elements should be replaced frequently and checked for proper connection and grounding Gas discharge types are by far the most robust cost effective means of protection The registered I S equipment meets all isolation and safety requirements of FCC Part 68 DOC CS 03 UL 913 and CSA C22 2 No 157 However lightning strikes are not predictable or co...

Страница 11: ...to 140 F 40 C to 60 C Relative humidity 95 non condensing maximum Maximum safe wiring distance between IBU and I S telephone Standard wire types 1 mile Using GTC 60059 001 conductor 1 5 miles Using GTC 60021 301 conductor 1 5 miles Wiring Construction Twisted pair Type Shielded Conductor size minimum 24 AWG Wiring loop resistance maximum 275 ohms Wiring capacitance maximum 0 316 uF Shielded cable ...

Страница 12: ... Intrinsically safe Interface Voltage maximum 8 volts Resistance minimum 66 ohms Current limited maximum 136 mA Indicators I S Loop Current I S LOOP GRN I S Lock Detect I S LOCK GRN Telephone Line Loop Current TELCO YEL Hook HOOK YEL Mechanical Housing construction Glass reinforced polyester Housing dimensions 9 39 W 13 16 H 7 46 D inches 238 5 334 3 189 5 mm Enclosure rating UL Type 3R rainproof ...

Страница 13: ...ompatible Output 0 dBm IBU TELCO Line 105 dB SPL 1 kHz Audio signal loss 18 AWG 1 3 dB mile NOTE Must be connected in accordance with Pub 42004 380 Control Drawing 73242 Mechanical Housing construction Glass reinforced Polyester Housing dimensions Model 262 001 8 02 W 9 52 H 6 86 D inches 203 7 241 8 174 2 mm including handset 3 86 D 98 mm without handset Model 272 001 9 39 W 13 16 H 7 46 D inches...

Страница 14: ... of the Contractor s personnel from the work site Re performance of services shall be Buyer s sole and exclusive remedy and in no event shall GAI Tronics warranty obligations with respect to services exceed 100 of the total cost of the services provided hereunder Warranty Periods Every claim by Buyer alleging a defect in the goods and or services provided hereunder shall be deemed waived unless su...