Pub. 43004-034C
Model 13353, 13363, and 13373 Addressable Amplified Speakers
Page: 52 of 52
f:\radio products-draft\gtc 43004\43004-034c\43004-034c.doc
05/10
CARD Suite Information for Addressable Amplified Speaker No. 4:
In this example, Addressable Amplified Speaker No. 4 is part of the East Campus and Dorm Zone areas
and can be accessed via addresses 104#, 112#, 113# and 99#. If any other code is entered, Speaker 4 will
remain inactive. Other notable programmed parameters for this speaker are:
•
Addresses 104, 112, and 113 will provide a contact closure output when active, but it will deactivate
within a few seconds after the broadcast has ceased.
•
Address 99 (All Call) will also provide a contact closure output when active, but the closure will
remain active for 3.00 seconds after the broadcast has ceased.
•
Low Battery Alert is not activated.
•
It is programmed for Voice Switch Mode with a voice switch silence limit programmed for 5
seconds.
•
Automatic Level Adjustment is disabled.
Содержание 13353
Страница 2: ......