13-4.6 Burner Oil Pressure
The Burner pump oil pressure is measured using a pressure gauge fitted into the bleed/
pressure gauge port of the pump. An allen key is used to set the pressure.
Do not adjust the pressure without the use of a gauge.
BLEED & PRESSURE GAUGE PORT
INCREASE
DECREASE
Fig. 13-4e Oil Pressure Adjustment
CAUTION
Only fit and remove
pressure gauge when
the Boiler is off.
Note
The recommended settings for the Burner
oil pressure are shown on pages 45 & 46.
Settings should not differ greatly from the
settings given.
Fig. 13-4f Pump Single and Two Pipe Operation
SPECIAL HORSE
SHOE WASHER
FITTED
UNDER SCREW
INLET
Danfoss
Type BFP 11 R3
RETURN
PORT
PLUGGED
INLET
PORT
RETURN
PORT
Danfoss
Type BFP 11 R3
SCREW FITTED
WASHER REMOVED
SINGLE PIPE OPERATION
SINGLE PIPE OPERATION
SINGLE PIPE OPERATION
SINGLE PIPE OPERATION
SINGLE PIPE OPERATION
TWO PIPE OPERATION
TWO PIPE OPERATION
TWO PIPE OPERATION
TWO PIPE OPERATION
TWO PIPE OPERATION
13-4.7 Burner Oil Pump
An ECOFLAM Burner with Danfoss pump is used on Thermecon Oil Boilers. Pumps can
be set for single and two pipe operation.
Floor standing Boilers are supplied with the Burner pump set for single pipe operation.
Wall mounted Boilers are supplied with the Burner pump set for two pipe operation.
IMPORTANT
When cover has to be removed - do not damage filter or seal.
Ensure cover is refitted correctly and that it does not leak.
Note
If no special washer is available
Single Pipe Operation can be
achieved by removing screw.