83
ENGLISH
83
Machine actions
Causes
Solutions
The machine grinds the
coff ee beans but no coff ee
is brewed (see note).
There is no water.
Fill the water tank and prime the circuit
(see the "Manual Rinse Cycle" chapter).
The brew group is dirty.
Clean the brew group (see the "Weekly
Cleaning of the Brew Group" chapter).
This might occur when the ma-
chine is automatically adjusting
the dose.
Brew some cups of coff ee as described
in the “Gaggia Adapting System”
chapter.
The dispensing spout is dirty.
Clean the dispensing spout.
The coff ee is too weak (see
note).
This might occur when the ma-
chine is automatically adjusting
the dose.
Brew some cups of coff ee as described
in the “Gaggia Adapting System”
chapter.
The ground coff ee is too coarse.
Change coff ee blend or adjust grind-
ing as explained in the “Adjusting the
Ceramic Coff ee Grinder” chapter.
Coff ee is brewed slowly
(see note).
The coff ee grind is too fi ne.
Change coff ee blend or adjust grind-
ing as explained in the “Adjusting the
Ceramic Coff ee Grinder” chapter.
The circuits are clogged.
Perform a descaling cycle.
The brew group is dirty.
Clean the brew group (see the “Weekly
Cleaning of the Brew Group” chapter).
Coff ee leaks out of the
dispensing spout.
The dispensing spout is clogged.
Clean the dispensing spout and its
holes.
Note:
These problems can be considered normal if the coff ee blend has been
changed or if the machine has just been installed. In this case, wait until
the machine performs a self-adjusting operation as described in the “Gaggia
Adapting System” chapter.