ENGLISh
29
7 - FUNCTION / USE AND PROGRAMMING
INTRODUCTION
The programming software permits the checking of the following
operations:
- handling of 1 - 2 coffee units
- control of four different coffee doses for each unit
- simultaneous function of both coffee and tea units
- volumetric check on coffee measures
- simulated measure programming
- filling level check and control
- system supervision through alarms
- continuos, delivery time-out and further functions
- serial connection with accounting devices
6.5 REPLACEMENT OF THE THERMOSTAT TO
REDUCE THE COFFEE DISPENSING
GROUP TEMPERATURE (OPTIONAL).
Remove cup heating bowl (1). Disconnect group thermostat (2) (Code
DM1561 – T 103°C) and replace it with the lower temperature thermo-
stat (Code DM1736 – T 98°C), included in the machine equipment.
1
2
Fig.6.07
T1 – single espresso coffee
T2 – double espresso coffee
T3 – single long coffee
T4 – double long coffee
T5 – Programming/continuos
Cod. AS0146/CL
H
= 85 mm
Cod. 26G0112
H
= 95 mm
Cod. 6301004010
H
= 100 mm
Cod. 6001023000
H
= 92 mm
H1
= 120 mm
WITHOUT SPOUTS
6.6
SPOUTS INCLUDED IN THE
SUPPLY.
No. 4 spouts are supplied with the machine to di-
spense one or two coffees.
The figure (beside) shows the different distances from
the cup-holding tray (H), depending on the different
types of spouts fitted on the filter holder.
Fig.6.08
Содержание GD compact
Страница 2: ......
Страница 4: ......
Страница 80: ...GD 1 GR COMPACT CIRCUITO DI COMANDI CONTROL CIRCUIT STEUERKREIS CIRCUIT DE COMMANDE CIRCUITO DE MANDO ...
Страница 81: ...GD 2 GR COMPACT CIRCUITO DI COMANDI CONTROL CIRCUIT STEUERKREIS CIRCUIT DE COMMANDE CIRCUITO DE MANDO ...
Страница 82: ...GE 1 GR COMPACT CIRCUITO DI COMANDI CONTROL CIRCUIT STEUERKREIS CIRCUIT DE COMMANDE CIRCUITO DE MANDO ...
Страница 83: ...GE 2 GR COMPACT CIRCUITO DI COMANDI CONTROL CIRCUIT STEUERKREIS CIRCUIT DE COMMANDE CIRCUITO DE MANDO ...
Страница 84: ......