Rev. 00 OCTOBER 2009
Page / 06
GAGGIA
04 OPERATING LOGIC
4.2. Control ringnut and valve
No.
DESCRIPTION
1
Mushroom valve cap
2
Spring for mushroom valve
3
Mushroom valve support
4
Mushroom valve
5
Sealing OR
1
2
3
4
5
When dispensing coffee the mushroom valve opens at 4 bar +/- 0.5
Manual opening when dispensing water
Manual opening when dispensing steam
02
TOTAL STROKE
COFFEE CLOSED
-30° + 30°
Valve opening
stroke
Valve closing
stroke
STEAM
OPEN
WATER
OPEN
Extra stroke
Extra stroke
Содержание Brera
Страница 8: ...Rev 00 OCTOBER 2009 CHAPTER 2 TECHNICAL SPECIFICATIONS ...
Страница 11: ...Rev 00 OCTOBER 2009 CHAPTER 3 BRIEF INSTRUCTIONS ...
Страница 15: ...Rev 00 OCTOBER 2009 CHAPTER 4 OPERATING LOGIC ...
Страница 22: ...Rev 00 OCTOBER 2009 CHAPTER 5 SERVICE MODE ...
Страница 25: ...Rev 00 OCTOBER 2009 CHAPTER 6 SERVICING AND MAINTENANCE ...
Страница 28: ...Rev 00 OCTOBER 2009 CHAPTER 7 DISASSEMBLY ...
Страница 37: ...Rev 00 OCTOBER 2009 CHAPTER 8 NOTES ...
Страница 38: ...Rev 00 OCTOBER 2009 Page 01 GAGGIA 08 NOTES 01 ...
Страница 39: ...Rev 00 OCTOBER 2009 CHAPTER 9 WATER CIRCUIT DIAGRAM ...
Страница 41: ...Rev 00 OCTOBER 2009 CHAPTER 10 ELECTRICAL DIAGRAM ...
Страница 42: ...Rev 00 OCTOBER 2009 Page 01 GAGGIA 10 WATER CIRCUIT DIAGRAM 10 1 Wiring diagram 01 ...