The brew group cannot be
inserted.
The brew group is not in the correct
position.
The brew group was not put in rest
position before it was placed back.
Make sure that the lever is in
contact with the base of the brew
group and that the hook of the
brew group is in the correct
position.
Reset the machine by switching it
on and off. Place the drip tray and
the coffee grounds container back.
Leave the brew group out. Close
the maintenance door and switch
the machine on and off. Then try
to reinsert the brew group.
The machine is still in the descaling
procedure.
You cannot remove the brew
group when the descaling process
is active. First complete the
descaling process and then
remove the brew group.
The coffee has too little
crema or is watery.
The grinder is set to a coarse setting.
Adjust the grinder to a finer setting.
The coffee blend is not the correct
one.
Change the coffee blend.
The machine is performing its self-
adjustment.
Brew a few cups of coffee.
The brew group is dirty.
Clean the brew group.
Coffee is leaking from the
coffee dispensing spout
The coffee dispensing spout is
clogged.
Clean the coffee dispensing spout
and its holes using a pipe cleaner.
The coffee is not hot
enough.
The cups you use are cold.
Preheat the cups by rinsing them
with hot water.
The temperature is set too low.
Check the menu settings.
Set the temperature to high in the
menu.
You added milk.
Whether the milk you add is warm
or cold, it will always decrease the
temperature of the coffee to some
extent.
The machine grinds the
coffee beans, but coffee
does not come out.
The grind is set too fine.
Adjust the grinder to a coarser
setting.
The brew group is dirty.
Clean the brew group.
The coffee dispensing spout is dirty.
Clean the coffee dispensing spout
and its holes with a pipe cleaner.