Installation Procedure
en-us
Flush fitting:
3.
Connect the appliance to the mains and check that it
works correctly.
4.
For installation flush with surrounding surfaces only:
Note:
Make sure that everything is working correctly
before grouting.
Grout the surrounding gap with a suitable
temperature-resistant silicone adhesive (e.g.,
OTTOSEAL
®
S 70). Smooth the joint seal with a
smoothing agent recommended by the manufacturer.
Heed the processing instructions for the silicone glue.
Only start up the appliance after the silicone glue is
completely dry (at least 24 hours, depending on the
room temperature).
NOTICE
Unsuitable silicone adhesive causes permanent
discoloration to natural stone countertops.
Connect Electrical Supply
Refer to data plate for more information. See "Service"
for data plate location.
The branch-circuit breakers ampacity, the wire sizes and
the connections must be conform to the requirements of
the National Electrical Code or Canadian Electrical Code
and all local codes and ordinances.
Attach flexible conduit to the junction box. Connect the
lead wires to the junction box supply wires in proper
phase:
▯
black (L1) to black
▯
red (L2) to red
▯
green to ground
The mains connecting cable must at least correspond to
the type SJTO 3x16 AWG 105°C. The mains connecting
cable must only be purchased through and connected by
an authorised specialist.
Connection with a plug
▯
Plug has to be conform with NEMA
CONFIGURATIONS FOR PLUGS AND
RECEPTACLES.
▯
The appliance must be properly grounded.
▯
Plug must be rated not less than type 6-20 P (2-pole 3-
wire grounding).
▯
Only a qualified electrician should connect the plug.
▯
Install a socket outlet earthed in accordance with
regulations approx. 27" (700 mm) above the floor
behind the appliance. The socket outlet must still be
accessible after installation.