Refer to the operating instructions of the fan
module for details of how to install it.
Depending on the installation situation
, three
variants of connection to a fan module are possible:
Installation situation 1
(Fig. 9-11)
Height of the worktop ≥ 90 cm, width of the cabinet
at least 60 cm, compact design, no additional
piping necessary, attachment plate (AS 081-051)
must be used
–
Saw out
the base plate in the built-in cabinet for
the fan module.
– When
aligning
the fan module, for flow dynamic
reasons you must make sure that the inserted
opening fits
over the fan wheel in the fan
module
.
–
Fit
the fan module in the base cabinet and fit the
attachment plate (AS 081-051) on the fan module.
Seal the free opening in the AS 081 with the
included cover.
–
Shorten
the pipe connection piece on the VL 051
so that it will protrude into the attachment plate
by no more than 10 mm. Stick the included
sealing tape onto the base plate of the VL 051
around the pipe connection piece.
–
Place
the VL 051 with the pipe connection piece
directly in one of the openings of the AS 081. In
the event of a greater distance between VL 051
and AS 081, you can bridge the space between
them with a flexible aluminium pipe (DN 125 mm).
–
Make sure
that the engaging lugs on the
appliance lie exactly on the clamping springs.
Press the appliance firmly into the worktop. The
engaging lugs on the appliance 'snap’ into the
clamping springs.
– At the front,
fix
the hob clamping element onto
the worktop from below until the appliance is
pressed on evenly (Fig. 11). If the worktop is
less than 36 mm thick, place the hob clamping
element under it.
–
Cut off
protruding sealing tape.
13
Fig. 11
min.
600
min.
600
min.
900
490
50
156
222
500
min.
560
20
500
min.
600
min.
900
AS 0
81-
051
GB
031
min.
560
min.
600
Fig. 9
Fig. 10