Safety Codes and Standards

This appliance complies with the latest version of one or 
more of the following standards:

z

z

CAN/CSA C22.2 No. 61 - Household Cooking Ranges

z

z

UL 858 - Household Electric Ranges

z

z

CAN/CSA C22.2 No. 150 Microwave Ovens

z

z

UL 923 - Microwave Cooking Appliances

z

z

UL 507 - Electric Fans

z

z

CAN/CSA C22.2 No. 113 - Fans and Ventilators

z

z

CSA C22.2 No. 64 - Household Cooking and Liquid-
Heating Appliances

z

z

UL 1026 - Electric Household Cooking and Food Serv-
ing Appliances

It is the responsibility of the owner and the installer to 
determine if additional requirements and/or standards 
apply to specific installations.

Grounding Instructions

This appliance must be grounded. In the event of an 
electrical short circuit, grounding reduces the risk 
of electric shock by providing an escape wire for the 
electric current. This appliance is equipped with a cord 
having a grounding wire with grounding plug. The plug 
must be plugged into a outlet that is properly installed 
and grounded.

WARNING

Improper use of the grounding can result in a risk 
of electric shock.

Consult a qualified electrician or serviceman if the 
grounding instructions are not completely understood, 
or if doubt exists as to whether the appliance is properly 
grounded. 
Do not use an extension cord. If the power supply cord 
is too short, have a qualified electrician or serviceman 
install an outlet near the appliance. 
The installer must perform a ground continuity check on 
the power outlet box before beginning the installation 
to insure that the outlet box is properly grounded. If not 
properly grounded, or if the outlet box does not meet 
Electrical Requirements, a qualified electrician should 
be employed to correct any deficiences. 

Clearances and Dimensions

z

z

For safety considerations, do not install Microwave 
Built-in Drawer in any combustible cabinetry which 
is not in accord with the stated clearances and 
dimensions in the "Microwave Built-in Drawer 
Measurements” section following. See Figure 3 
(standard installation) or Figure 4 (flush installation).

z

z

Dimensions that are shown in Figure 3 (standard 
installation) or Figure 4 (flush installation) must be 
used. Given dimensions provide minimum clearance. 
Locate electrical outlet in the shaded area in the upper 
left-hand corner of the cutout. See Figure 6.

z

z

Supporting surface must be solid and level. Pay 
special attention to the floor of the cabinet opening 
on which the Microwave Built-in Drawer will sit. The 
floor of the opening should be constructed of plywood 
strong enough to support the weight of the oven 
(about 100 pounds).

z

z

Check the location where the Microwave Built-in 
Drawer will be installed for proper electrical supply.

z

z

Your oven can be built into a cabinet or wall as a 
stand-alone unit or under a built-in gas or electric wall 
oven and the followings:

GAS 

COOKTOPS

ELECTRIC 

COOKTOPS

INDUCTION 

COOKTOPS

VG231214CA
VG232214CA
VG264214CA
VG295114CA
VG295214CA
VG414210CA
VG424210CA
VG491210CA

CE490612

VE230614
VE260614

VF230614
VF414610

VK230714
VK414610
VP230614
VP414610
VR230614
VR414610

CI481612
CI491602
CI491612
CX491610
VI414610
VI424610
VI491610

z

z

Check to be sure that there is a clearance of 2 inches 
or greater between the top of the Microwave Built-in 
Drawer unit and the bottom of a built-in wall oven 
above it.

z

z

The microwave interior will easily accommodate a 
9" x 13" oblong dish or a bag of microwave popcorn.

Содержание MW 420 620

Страница 1: ...Gaggenau Installation instructions 2 Instructions d installation 9 Instrucciones de instalaci n 14 MW 420 620 Microwave Built in Drawer Micro ondes int gr dans le tiroir Microondas gaveta Incorporado...

Страница 2: ...with the door open since open door operation can result in harmful exposure to microwave energy It is important not to defeat or tamper with the safety interlocks b Do not place any object between the...

Страница 3: ...the outlet box does not meet Electrical Requirements a qualified electrician should be employed to correct any deficiences Clearances and Dimensions z z For safety considerations do not install Microw...

Страница 4: ...s Use caution when reaching behind or under appliance z z Read and understand the contents of this Installation Manual before installing the Microwave Built in Drawer z z Remove all packing material b...

Страница 5: ...m 217 8 556 mm 38 3 8 974 mm 145 8 371 mm 16 5 16 414 mm 14 5 8 372 mm 23 1 2 597 mm 24 or 27 610 or 686 mm 36 914 mm 221 8 562 mm Frontview cut out Suggested location of electrical outlet Anti Tip Bl...

Страница 6: ...nstallation Steps Anti Tip Block Installation Instructions The anti tip block reduces the risk of drawer tipping when installed properly Install the anti tip block 14 13 16 inches above the installati...

Страница 7: ...person Can also be installed using an electrical outlet in an adjacent cabinet within the area where the provided electrical cord can reach Always check electrical codes for requirements Drawer Insta...

Страница 8: ...al AVERTISSEMENT Si les informations contenues dans ce manuel ne sont pas suivies la lettre un incendie ou un choc peuvent causer des dommages mat riels ou corporels PR CAUTIONS POUR VITER LE RISQUE D...

Страница 9: ...la zone de prise est correctement mise la terre S il n est pas correcte ment mise la terre ou si la bo te de sortie ne r pond pas aux exigences lectriques un lectricien qualifi doit tre utilis e pour...

Страница 10: ...es d installation avant d installer le Tiroir micro ondes z z Retirer tous les mat riaux d emballage avant de con necter au secteur z z Le propri taire et l installateur sont responsables d assurer la...

Страница 11: ...414 mm Environ 46 po 1 168 4 mm 145 8 po 372 mm 23 1 2 po 597 mm 24 po ou 27 po 610 ou 686 mm 36 po 914 mm 22 1 8 po 562 mm D coupe vue de face Emplacement sugg r de la prise lectrique Bloc antibascu...

Страница 12: ...o 25 mm 36 po 914 mm 243 16 po 614 mm 221 8 po 562 mm D coupe vue de facet Tasseau 14 5 8 po 371 mm 165 8 po 422 mm D coupe 6 po 152 mm 4 po 102 mm 5 po 127 mm 2 1 4 po 57 mm 15 8 po 41 mm 1 2 po 13 m...

Страница 13: ...mentation fourni avec l appareil V rifiez toujours les normes et le code lectriques de votre r gion Installation du tiroir 1 Placer le four pr s de l ouverture du mur ou de l armoire Brancher le cordo...

Страница 14: ...E ELECTRICIDAD z z LEA Y GUARDE ESTAS INSTRUCIONES PARA FUTURA REFERENCIA Advertencia especial 14 Espacios libres y dimensiones 15 Desembalaje de su Microondas gaveta Incorporado 15 Notas importantes...

Страница 15: ...e todos los materiales de embalaje que est n dentro de la gaveta NO RETIRE LA CUBIERTA DE LA GU A DE ONDAS ubicada en la parte superior del Microondas gaveta Incorporado z z Verifique que la gaveta no...

Страница 16: ...n sugerida del tomacorriente Bloque antivuelco La base debe soportar hasta 100 libras 1413 16 376 mm 6 152 mm 4 102 mm 5 127 mm 3 1 2 89 mm 1 1 2 38 mm 7 8 22 mm de sobreposici n 1 2 13 mm rea visible...

Страница 17: ...ableado o tuber as que puedan estar presentes en la pared ADVERTENCIA La unidad puede voltearse y causar derrames y posibles quemaduras u otro tipo de lesiones si el bloque antivuelco no est instalado...

Страница 18: ...asta donde se pueda extender el cable el ctrico Siempre verifique los c digos el ctricos para ver los requisitos Instalaci n de la gaveta 1 Coloque el Microondas gaveta Incorporado al lado de la abert...

Страница 19: ......

Страница 20: ...966545 TINSLB042MRR0 Gaggenau BSH Home Appliances Ltd 1901 Main Street Suite 600 Irvine CA 92614 1 877 4GAGGENAU USA www gaggenau usa com Gaggenau Hausger te GmbH Carl Wery Stra e 34 81739 M nchen GER...

Отзывы: