Fault
Error
Causes
Possible remedy
The
…
symbol will
appear after a few sec-
onds.
The vacuum cannot be
created properly.
The glass lid has not been
closed properly.
Open and close the glass lid
again. When doing so, lightly
press on the glass lid for the first
few seconds.
The seal on the glass lid is not
fitted properly or is malfunction-
ing.
Check the seal.
The seal on the glass lid has mis-
shaped.
Gently press the seal to
straighten it out.
The lid on the external vacuum-
sealing container has not been
closed properly.
Check the position of the vac-
uum-sealing lid. Only use suit-
able vacuum-sealing containers.
The external vacuum-sealing con-
nection is not positioned cor-
rectly on the vacuum-sealing
chamber's air outlet.
Check the position of the exter-
nal vacuum-sealing connection.
The
…
symbol will
appear after the pump
has been running for
2 minutes.
It is taking too long to
create a vacuum. Your
selected vacuum-seal-
ing level cannot be
reached.
As the temperature rises, liquids
begin to heat. At this point, the
process of creating a vacuum
stops.
Only vacuum-seal cold liquids.
If the vacuum-sealing chamber is
wet, wipe it dry.
Heat-seal the vacuum-sealing
bag early if large bubbles form.
Select a lower vacuum-sealing
level.
The vacuum-sealing
process will not start.
The
²
symbol does not
appear even though the
lid is closed.
The appliance is not
detecting the lid.
The door switch on the glass lid
is not working or is not being
detected by the appliance.
Call Customer service.
If you try to operate the
appliance several times
in succession, the vac-
uum-sealing process
seems to run as normal
but the bag is not heat-
sealed.
The thermal switch on the heat-
sealing transformer has been
triggered.
Allow the appliance to cool for at
least 10 minutes. Then try again.
Allow the appliance to cool for at
least 2 minutes between vacuum-
sealing operations.
The vacuum-sealing
process is taking lon-
ger and longer.
There is too much moisture in the
pump system.
The appliance monitors the vac-
uum-sealing as it progresses. If
too much liquid is retained in the
pump oil, the
¢
symbol will
appear. Initiate drying.
The pump system is extremely
hot.
Allow the appliance to cool and
then try again.