en-us
Checking the installation
10
junction box
flexible conduit approx. 3 ft. (900 mm)
Power supply
All models must be connected with the included 39" (1 m) flexible conduit.
Models
240 V AC, 3-wire, 60 Hz system: cir-
cuit breaker
208 V AC, 3-wire, 60 Hz system: cir-
cuit breaker
CI 482 602
30 A
30 A
CI 492 602
50 A
50 A
5.2 Connecting electrical supply
WARNING
Before installing, turn power OFF at the service panel.
▶
Lock service panel to prevent power from being turned
ON accidentally.
Note: If the cooktop is installed and connected as speci-
fied here, it will be grounded in compliance with the Na-
tional Electrical Code.
1.
Install a suitable junction box (not furnished).
The branch-circuit breakers ampacity, the wire sizes
and the connections must conform to the requirements
of the National Electrical Code or Canadian Electrical
Code and all local codes and ordinances.
2.
Attach the flexible conduit to the junction box.
3.
Connect the lead wires to the junction box supply wires
in proper phase.
1
2
3
4
5
6
7
1
Red wires
2
UL listed wire connectors
3
Green (or bare) ground wire (from appliance)
4
Cable from home power supply
5
Black wires
6
Junction box
7
Flexible conduit from appliance
– Black (L1) to black
– Red (L2) to red
– Green or bare to ground
Checking the installation
6 Checking the installation
Checking the installation
Check if your unit is working properly after you have com-
pleted the installation steps.
WARNING
Before you turn on power supply, make sure all controls
are in the OFF position.
1.
Remove everything from the cooktop surface including
stickers.