20
Saturation indicator
Operating procedure
The most effective method of removing
vapours produced during cooking is to:
❑
Switch the ventilator ON
as soon as you begin cooking.
❑
Switch the ventilator OFF
a few minutes after you have finished
cooking.
Switching the fan ON:
❑
Press the
1, 2
or
3
button.
Switching the fan OFF:
❑
Press the
0
button
.
Intensive setting:
Maximum power is obtained at the
intensive setting. It is only required for short
intervals.
❑
The
Int
key for the intensive level
should be pressed when browning
and frying in an open pan.
If you have switched on the hood by
selecting the intensive level, it will be
switched off again automatically after
5 minutes.
❑
If you press the
Int
key while the hood is
running at fan level
1, 2
or
3,
the
electronic control will switch back
automatically to the previously selected
fan level after 5 minutes.
❑
If you would like to end the intensive level
before
the five minutes have elapsed,
press the
0
key (“Motor off”) or select a
different level. It is possible to switch off
the extraction function at any time by
pressing the
0
key (motor “off”).
Special functions:
Intensive time:
❑
You can set the intensive level running
time to 3, 5 or 10 minutes by simulta-
neously pressing the
Int
key and the
1, 2
or
3
key and you can store this
setting. When delivered, the appliance is
set to five minutes, i.e. the combination
of the
Int
key and the key
2.
Fan follow-on:
❑
Delayed shut-off is possible at any level.
First press the required key
1, 2, 3
or
Int
and then press the
key.
The delayed shut-off time for all levels is
ten minu-tes. After these ten minutes,
the ventilation switches off, but the
lighting stays on.
Interval ventilation:
❑
Interval ventilation is a special feature of
this appliance which periodically
activates the fan for five minutes every
hour. You can activate this function by
simultaneously pressing the
0
key and,
depending on the required extraction
capacity, the
1, 2
or
3
key.
This mode of operation is indicated by
alternating illumination of the
key
together with the corresponding fan level
indicator.
You can switch off interval ventilation by
pressing the
0
key.
Lighting:
❑
Briefly press the
button to switch the
light on and off.
❑
The light can be switched on at any
time, even though the fan is switched off.
❑
Adjusting the brightness:
Hold down the
button until the
desired brightness is obtained.
Light
Fan OFF
Intensive setting
Fan follow-on
Fan settings
Содержание AW 260-170
Страница 102: ...102 AD260 261 012 2 12 2 65 m AD260 261 022 2 49 3 05 m D 4 Pa 0 04 mbar...
Страница 103: ...103 AD260 261 112 2 23 2 65 m AD260 261 122 2 49 3 05 m...
Страница 104: ...104 T E 15 2002 96 waste electrical and electronic equipment WEEE...
Страница 105: ...105 A...
Страница 106: ...106 Off 1 2 3 0 Int 5 Int 1 2 3 5 5 p 0 Off 0 Off...
Страница 107: ...107 x Int 1 2 3 3 5 10 9 Int 2 1 2 3 Int 0 1 2 3 0...
Страница 108: ...108 F 30 F 1 2 1...
Страница 109: ...2 3 1 3 A 1 2 3 1 2 1 2 1 109...
Страница 110: ...110 461731...
Страница 111: ...111 F 1 FD 3 12 Volt 20 Watt G4 4 5 1 2...
Страница 112: ...112 TRGI 50 mm 650 mm 1 S 550 mm 1 S...
Страница 115: ...115 1 30 m 3 mm LS kg 20 5 70 cm 90 cm 21 0 22 0 22 5...
Страница 116: ...116 1 2 3 550 mm 650 mm 4 4 2 8 mm 6 5 2 2 30 172 476 36 5 400 min 550 Elektro min 650 Gas 216...
Страница 117: ...8 9 12 2 1 2 3 13 10 11 7 117...
Страница 118: ...118 Notizen...
Страница 119: ...119 Notes...
Страница 120: ...120 Notities...
Страница 121: ...121 Note...
Страница 122: ...122 064 039 Noticias...
Страница 123: ...70 cm AA 260272 90 cm AA 260292 AA 260112...