background image

23

Proper use

Clean the extractor hood thoroughly before

using for the first time.

Before cleaning and servicing the extractor

hood, isolate it from the power supply by pulling

out the mains plug or switching off the fuse.

Bulbs (especially halogen bulbs) become very

hot during operation. Even some time after the

appliance has been switched off, there is still a

risk of burns!

Before changing bulbs, isolate the extractor

hood from the power supply and leave the bulbs

to cool down!

Do not operate the extractor hood without bulbs

inserted.

Always switch on the extractor hood if a

hotplate is being used. If the extractor hood is

not switched on, condensation may form. As a

result, the appliance may corrode.

Do not place any objects

on the extractor hood.

There shall be adequate

ventilation of the room

when the range hood is

used at the same time as

appliances burning gas or other fuels (not

appliacable to appliances that only discharge

the air back into the room).

RISK OF FIRE

Do not flambé under the extractor hood or work

with a naked flame. When switched on, the

extractor hood draws flames into the filter. There is

a risk of fire due to deposits on the grease filter!

Do not leave pans, frying pans or deep-fat

fryers unattended if you are cooking food with

oils or fats, e.g. chips. Overheated oils or fats

can easily ignite!

A risk of fire can be prevented by cleaning the

grease filters regularly and changing the

activated-carbon filter in good time.

Never operate the extractor hood without

grease filters.

Correct installation

Check the manufacturer’s specifications for the

cooker to determine whether an extractor hood

can be operated over it.

If the manufacturer of the cooker has not

specified any significant safety distances, the

following minimum distances apply

550 mm between electric hob and the lower

edge of the extractor hood, Fig. 1.

650 mm between gas hob (upper edge of pan

support) and the lower edge of the extractor

hood, Fig. 1.

If various cookers are used, the greatest

indicated distance applies.

The width of the extractor hood must

correspond to the width of the cooking area.

The extractor hood must not be installed over a

solid fuel heating appliance which may be a fire

risk (e.g. flying sparks) unless the heating

appliance has a closed, non-detachable cover

and the country-specific regulations are

observed. This restriction does not apply to gas

cookers and gas hobs.

To avoid damaging the hob, cover it when

installing the extractor hood.

Содержание AW 221190CN

Страница 1: ...AW 221190CN Gaggenau zh en Operating and installation instructions...

Страница 2: ...2 1 Fig 1 GAS 1 ELECTRO zh 03 18 en page 19 34...

Страница 3: ...3 4 4 4 5 5 5 6 7 7 8 8 8 9 11 12 12 12 13 14 14 15 16 16 17 18...

Страница 4: ...4 2002 96 EC WEEE F 1 E FD...

Страница 5: ...5...

Страница 6: ...6 4 Pa 0 04 mbar Technische Regeln Gasinstallation TRGI 50 mm 2 15 1 5 kW 2...

Страница 7: ...7 550 mm 1 650 mm 1...

Страница 8: ...8 min 126 mm min 580 mm max 1 445 mm min 170 mm 170 mm...

Страница 9: ...9 1 2 3 Int 0 Int 2 1 2 3 Int 2 2 0 0 0...

Страница 10: ...10 Int 1 2 3 3 4 2 Int 2 1 2 3 Int 10 10 5 0 1 2 3 0 F 30 F F...

Страница 11: ...11 1 2...

Страница 12: ...12 1 2 3 1 2 2 1 2 3 4...

Страница 13: ...13 1 2 3 4 1 2 3 4 5...

Страница 14: ...14 150 mm 150 mm 150 mm 120 mm 150 mm 177 cm2 120 mm 113 cm2 150 mm 120 mm...

Страница 15: ...15 3 mm LS 1 30 m EC...

Страница 16: ...16 Poroton 40 kg 1 2 3 2x 8 mm 2x 8 mm 4 5 3 Nm...

Страница 17: ...17 1 1 2 2 3 3 1 2 3 4 5...

Страница 18: ...GB 29539 2013...

Страница 19: ...ng modes 24 Exhaust air mode 24 Circulating air mode 24 Operating procedure 25 Cleaning and care 27 Removing and installing the grease filters 28 Removing and installing the metal mesh grease filters...

Страница 20: ...ure that the old appliance is kept childproof until it is disposed of Before using the appliance for the first time Note These operating instructions apply to several appliance models It is possible t...

Страница 21: ...ustomer service or a similarly qualified person to prevent hazardous situations Only a qualified technician may install including electrical connection service or repair the extractor hood Always isol...

Страница 22: ...bove gas hobs observe the appropriate national statutory regulations e g in Germany Technische Regeln Gasinstallation TRGI Observe the currently valid installation regulations and instructions of the...

Страница 23: ...e due to deposits on the grease filter Do not leave pans frying pans or deep fat fryers unattended if you are cooking food with oils or fats e g chips Overheated oils or fats can easily ignite A risk...

Страница 24: ...vated carbon filter and conveyed back into the kitchen An activated carbon filter must be installed to bind odours in circulating air mode see Removing and installing the grease filters The complete i...

Страница 25: ...uld be pressed when browning and frying in an open pan If you have switched on the hood by selecting the intensive level it will be switched off again automatically after 2 hours If you press the Int...

Страница 26: ...ou can activate this function by simultaneously pressing the 0 key and depending on the required extraction capacity the 1 2 or 3 key This mode of operation is indicated by alternating illumination of...

Страница 27: ...bsorb the grease particles from the kitchen fumes The filter mats consist of fire proof metal RISK OF FIRE As the filters become more saturated with greasy residue the flammability increases The funct...

Страница 28: ...culating air mode Under normal operation daily 1 to 2 hours the activated carbon filters must be replaced approximately 2x year The activated carbon filter is available from specialist outlets custome...

Страница 29: ...e of the same type and equivalent power see rating plate Note When inserting halogen bulbs do not touch the glass tube Therefore use a clean cloth when inserting the bulb 3 Reinsert the bulb cover 4 R...

Страница 30: ...ong rough exhaust air pipes a lot of pipe bends or pipe diameters less than 150 mm are used the air capacity will be less than optimum and there will be an increase in noise Use only pipes or hoses ma...

Страница 31: ...the earthed socket as directly as possible behind the flue duct The earthed socket should be connected via its own circuit If the earthed socket is no longer accessible following installation of the...

Страница 32: ...pacity Ensure that the depth of the drilled holes corresponds with the length of the screws Ensure that the wall plugs are secure Max weight 40 kg Design subject to modification in line with technical...

Страница 33: ...the holes for the safety screws Detach the extractor hood drill holes for the safety screws and press in wall plugs flush with the wall 2 Attach the extractor hood and screw in the safety screws tigh...

Страница 34: ...GB 29539 2013...

Страница 35: ...35 AD220182 AD220110 AD220312 AD220322 AD221312 AD221322...

Страница 36: ...Gaggenau Hausger te GmbH Carl Wery Stra e 34 D 81739 M nchen www gaggenau com 9000766017 EB 9308...

Отзывы: