background image

15

电气连接

在将电器连接到电源之前,请务必遵守

安全说明

章节中的说明和警告!

只有熟悉供电公司相关规定的、具备相应资格的电

气专业人员才能连接吸油烟机。

有受伤危险

如果吸油烟机的电源线损坏,必须由制造商、制造

商客户服务人员或具备相应资格的类似人员更换电

源线,防止出现危险状况。

只能将吸油烟机连接至正确安装的接地插座。

尽量将接地插座直接安装在烟道管后面。

应该通过接地插座自带的电路连接接地插座。

如果在安装吸油烟机后难以触及接地插座,则必须

安装一个固定连接的隔离开关。

如果需要固定连接

必须在安装侧提供隔离开关。触点间隙超过 3 mm

的开关和全电极断开装置可以作为隔离开关。这包

括 LS 开关、保险丝和接触器。

电气规格

拆除油脂过滤器后,可在电器内部的铭牌上查看所要求

的连接数据。

电源线长度:约 1.30 m。

本电器遵守 EC 射频干扰抑制规范。

Содержание AW 221190CN

Страница 1: ...AW 221190CN Gaggenau zh en Operating and installation instructions...

Страница 2: ...2 1 Fig 1 GAS 1 ELECTRO zh 03 18 en page 19 34...

Страница 3: ...3 4 4 4 5 5 5 6 7 7 8 8 8 9 11 12 12 12 13 14 14 15 16 16 17 18...

Страница 4: ...4 2002 96 EC WEEE F 1 E FD...

Страница 5: ...5...

Страница 6: ...6 4 Pa 0 04 mbar Technische Regeln Gasinstallation TRGI 50 mm 2 15 1 5 kW 2...

Страница 7: ...7 550 mm 1 650 mm 1...

Страница 8: ...8 min 126 mm min 580 mm max 1 445 mm min 170 mm 170 mm...

Страница 9: ...9 1 2 3 Int 0 Int 2 1 2 3 Int 2 2 0 0 0...

Страница 10: ...10 Int 1 2 3 3 4 2 Int 2 1 2 3 Int 10 10 5 0 1 2 3 0 F 30 F F...

Страница 11: ...11 1 2...

Страница 12: ...12 1 2 3 1 2 2 1 2 3 4...

Страница 13: ...13 1 2 3 4 1 2 3 4 5...

Страница 14: ...14 150 mm 150 mm 150 mm 120 mm 150 mm 177 cm2 120 mm 113 cm2 150 mm 120 mm...

Страница 15: ...15 3 mm LS 1 30 m EC...

Страница 16: ...16 Poroton 40 kg 1 2 3 2x 8 mm 2x 8 mm 4 5 3 Nm...

Страница 17: ...17 1 1 2 2 3 3 1 2 3 4 5...

Страница 18: ...GB 29539 2013...

Страница 19: ...ng modes 24 Exhaust air mode 24 Circulating air mode 24 Operating procedure 25 Cleaning and care 27 Removing and installing the grease filters 28 Removing and installing the metal mesh grease filters...

Страница 20: ...ure that the old appliance is kept childproof until it is disposed of Before using the appliance for the first time Note These operating instructions apply to several appliance models It is possible t...

Страница 21: ...ustomer service or a similarly qualified person to prevent hazardous situations Only a qualified technician may install including electrical connection service or repair the extractor hood Always isol...

Страница 22: ...bove gas hobs observe the appropriate national statutory regulations e g in Germany Technische Regeln Gasinstallation TRGI Observe the currently valid installation regulations and instructions of the...

Страница 23: ...e due to deposits on the grease filter Do not leave pans frying pans or deep fat fryers unattended if you are cooking food with oils or fats e g chips Overheated oils or fats can easily ignite A risk...

Страница 24: ...vated carbon filter and conveyed back into the kitchen An activated carbon filter must be installed to bind odours in circulating air mode see Removing and installing the grease filters The complete i...

Страница 25: ...uld be pressed when browning and frying in an open pan If you have switched on the hood by selecting the intensive level it will be switched off again automatically after 2 hours If you press the Int...

Страница 26: ...ou can activate this function by simultaneously pressing the 0 key and depending on the required extraction capacity the 1 2 or 3 key This mode of operation is indicated by alternating illumination of...

Страница 27: ...bsorb the grease particles from the kitchen fumes The filter mats consist of fire proof metal RISK OF FIRE As the filters become more saturated with greasy residue the flammability increases The funct...

Страница 28: ...culating air mode Under normal operation daily 1 to 2 hours the activated carbon filters must be replaced approximately 2x year The activated carbon filter is available from specialist outlets custome...

Страница 29: ...e of the same type and equivalent power see rating plate Note When inserting halogen bulbs do not touch the glass tube Therefore use a clean cloth when inserting the bulb 3 Reinsert the bulb cover 4 R...

Страница 30: ...ong rough exhaust air pipes a lot of pipe bends or pipe diameters less than 150 mm are used the air capacity will be less than optimum and there will be an increase in noise Use only pipes or hoses ma...

Страница 31: ...the earthed socket as directly as possible behind the flue duct The earthed socket should be connected via its own circuit If the earthed socket is no longer accessible following installation of the...

Страница 32: ...pacity Ensure that the depth of the drilled holes corresponds with the length of the screws Ensure that the wall plugs are secure Max weight 40 kg Design subject to modification in line with technical...

Страница 33: ...the holes for the safety screws Detach the extractor hood drill holes for the safety screws and press in wall plugs flush with the wall 2 Attach the extractor hood and screw in the safety screws tigh...

Страница 34: ...GB 29539 2013...

Страница 35: ...35 AD220182 AD220110 AD220312 AD220322 AD221312 AD221322...

Страница 36: ...Gaggenau Hausger te GmbH Carl Wery Stra e 34 D 81739 M nchen www gaggenau com 9000766017 EB 9308...

Отзывы: