Preparing the ceiling
•
The wall must be flat and horizontal.
•
Make sure that the ceiling can bear the applied
loads.
•
The provided screws and wall plugs are
suitable for solid masonry. On all other wall
types (e.g. plasterboard, porous concrete,
Poroton bricks) use the appropriate fasteners.
•
Ensure that the ceiling is capable of providing a
firm hold for mounting screws and plugs.
Weight in kg:
We reserve the right to construction changes within
the context of technical development.
WARNING: THIS APPLIANCE MUST BE EARTHED
IMPORTANT: Fitting a Different Plug:
The wires in the mains lead are coloured in
accordance with the following code:
Green and Yellow
– Earth
Blue
– Neutral
Brown
– Live
If you fit your own plug, the colours ofthese wires
may not correspond with the identifying marks on
the plug terminals.
This is what you have to do:
1
Connect the green and yellow (Earth) wire to
the terminal in the plug marked ‘E’ or with the
symbol (
), or coloured green or green and
yellow.
2
Connect the blue (Neutral) wire to the terminal
in the plug marked ‘N’ or coloured black.
3
Connect the brown (Live) wire to the terminal
marked ‘L’, or coloured red.
The extractor hood should only be con-nected to
an earthed socket that has been installed
according to relevant regulations.
If possible, site the earthed socket directly behind
the chimney panelling.
•
The earthed socket should be connected via its
own circuit.
•
If the earthed socket is no longer accessible
following installation of the extractor hood,
ensure that there is a permanently installed
disconnector.
If it is necessary to wire the extractor hood
directly into the mains:
The extractor hood should only be connected to the
electricity supply by a properly qualified electrician.
A separator must be installed in the household
circuit. A suitable separator is a switch that has a
contact gap of more than 3 mm and interrupts all
poles. Such devices include circuit breakers and
contactors.
몇
If the connecting cable for this
appliance is damaged, the cable must be replaced
by the manufacturer or his customer service or a
similarly qualified person in order to prevent serious
injury to the user.
Electrical connection
18
Exhaust-air
Recirculating air
42,5
44,5