background image

5

2. Features

1

V

entilation duct

2

Control panel

3

Grease filters

4

Lighting

Installation accessories for 

exhaust air mode

Stainless steel-design ventilation duct:

AD 010-016 

for ceiling heights of 

2.24 - 2.42 m

AD 010-026 

for ceiling heights of 

2.42 - 2.74 m

AD 010-036 

for ceiling heights of 

2.74 - 3.00 m

Aluminium-design ventilation duct:

AD 01

1-016 

for ceiling heights of 

2.24 - 2.42 m

AD 01

1-026 

for ceiling heights of 

2.42 - 2.74 m

AD 01

1-036 

for ceiling heights of 

2.74 - 3.00 m

Installation accessories for circulating 

air mode

Stainless steel-design ventilation duct:

AD 010-126

for ceiling heights of 

2.42 - 2.74 m

AD 010-136 

for ceiling heights of 

2.74 - 3.00 m

Aluminium-design ventilation duct:

AD 01

1-126

for ceiling heights of 

2.42 - 2.74 m

AD 01

1-136 

for ceiling heights of 

2.74 - 3.00 m

Fig. 2

1

2

3

4

Fig. 3

Motor off

Extraction level 1

Extraction level 2

Extraction level 3

Extraction level intensive

Delayed shut-off

Lighting

Grease filter

saturation display

Содержание AI 200

Страница 1: ...Operating and Assembly Instructions AI 200 AI 201 AI 202 AI 203 Extractor Hood...

Страница 2: ......

Страница 3: ...1 For your safety Page 3 1 2 Operating for the first time Page 4 1 3 About use Page 4 2 Features Page 5 3 Operation Page 6 8 4 Cleaning and care Page 9 10 5 Maintenance Page 11 6 Assembly instructions...

Страница 4: ...otes on use installation and maintenance of the appliance On the following page you will find important notes on safety and operation These will serve to ensure your personal safety and the lasting va...

Страница 5: ...ing more than 3 gas operated rings at the same time please operate the extractor hood at level 2 or higher This prevents a build up of heat in the appliance For safety reasons do not place any heavy o...

Страница 6: ...ime see chapter Cleaning and care Before operating the appliance for the first time check that the mains connection is in proper working order This appliance is labelled in accordance with the Europea...

Страница 7: ...2 m AD 011 026 for ceiling heights of 2 42 2 74 m AD 011 036 for ceiling heights of 2 74 3 00 m Installation accessories for circulating air mode Stainless steel design ventilation duct AD 010 126 for...

Страница 8: ...ation by pressing the key see Fig 4 When you briefly press the key the lighting is increased up to the maximum level You can dim the lighting to the required level by keeping the key pressed Fan level...

Страница 9: ...ess the Int key while the hood is running at fan level 1 2 or 3 the electronic control will switch back automatically to the previously selected fan level after 5 minutes see Fig 7 If you would like t...

Страница 10: ...f time for all levels is ten minu tes After these ten minutes the ventilation switches off but the lighting stays on Interval ventilation Interval ventilation is a special feature of this appliance wh...

Страница 11: ...s out of the holder repeat the operation for the other grease filters You can clean the stainless steel grease filters in a dishwasher at a maximum temperature of 65 C where it should be supported ver...

Страница 12: ...al filter must be replaced approximately once a year If no activated charcoal filter is installed kitchen smells will not be eliminated The activated charcoal filter KF 001 010 is available through yo...

Страница 13: ...tampering will render all warranty claims null and void Lamp replacement Caution disconnect the power supply before replacing lamps switch off the fuse Caution lamps may still be hot shortly after use...

Страница 14: ...e from the cooking surface to the bottom edge of the extractor hood is 600 mm for electrical appliances The minimum distance from the bottom edge of the pot stand to the bottom edge of the extractor h...

Страница 15: ...essible after installation The duct units listed below are available depending on the height of the ceiling Installation accessories for exhaust air mode Stainless steel design ventilation duct AD 010...

Страница 16: ...can only be used in exhaust air mode The exhaust air is conveyed upwards through an externally attached fan via a ventilation shaft or directly into the open air through the outer wall The extraction...

Страница 17: ...t the minimum distance between the hob and the extractor hood is maintained 600 mm for an electric hob and 650 mm for a gas hob Circulating air mode only there are four brackets which fix the circulat...

Страница 18: ...screws to the ceiling Circulating air mode only assemble the circulating air switch module and fix it to support frame Fig 22 and 23 Cut the flexible air pipe to the required length and fix it to the...

Страница 19: ...hich has no magnetic strips with 2 screws on the top of the support frame Fig 26 14 The second top chimney duct which has magnetic strips should be slightly bent open in order to slide over the first...

Страница 20: ...Gaggenau Hausger te GmbH Carl Wery Stra e 34 D 81739 M nchen www gaggenau com 9000232720 EB 8701 en...

Отзывы: