background image

1.2 Operating for the first time

Before operating the appliance for the first time,

please pay attention to the following notes:

– The appliance must be installed and connected

by a specialist before it is operated for the first
time.

– Conscientiously read through the operating and

assembly instructions before operating the
appliance for the first time.

– Remove the packaging from the appliance and

dispose of it properly! Pay attention to the fact
that there are accessories in the packaging!
Keep packaging elements out of the reach of
children!

– Thoroughly clean the appliance before using it

for the first time (see chapter “Cleaning and
care”).

– Before operating the appliance for the first time,

check that the mains connection is in proper
working order.

This appliance is labelled in accordance
with the European Directive 2002/96/EG
concerning used electrical and electronic
appliances (waste electrical and
electronic equipment – WEEE). The

guideline determines the framework for the return
and recycling of used appliances as applicable.

Check the appliance for transport damage before
installing it.

1.3 About use

The appliance is intended solely for use in the
household and must not be put to any other uses.

– In the event of malfunctions, first of all check the

household fuses. If the problem has nothing to
do with the power supply, please contact your
specialist dealer or your local Gaggenau after-
sales service.

4

Содержание AI 200

Страница 1: ...Operating and Assembly Instructions AI 200 AI 201 AI 202 AI 203 Extractor Hood...

Страница 2: ......

Страница 3: ...1 For your safety Page 3 1 2 Operating for the first time Page 4 1 3 About use Page 4 2 Features Page 5 3 Operation Page 6 8 4 Cleaning and care Page 9 10 5 Maintenance Page 11 6 Assembly instructions...

Страница 4: ...otes on use installation and maintenance of the appliance On the following page you will find important notes on safety and operation These will serve to ensure your personal safety and the lasting va...

Страница 5: ...ing more than 3 gas operated rings at the same time please operate the extractor hood at level 2 or higher This prevents a build up of heat in the appliance For safety reasons do not place any heavy o...

Страница 6: ...ime see chapter Cleaning and care Before operating the appliance for the first time check that the mains connection is in proper working order This appliance is labelled in accordance with the Europea...

Страница 7: ...2 m AD 011 026 for ceiling heights of 2 42 2 74 m AD 011 036 for ceiling heights of 2 74 3 00 m Installation accessories for circulating air mode Stainless steel design ventilation duct AD 010 126 for...

Страница 8: ...ation by pressing the key see Fig 4 When you briefly press the key the lighting is increased up to the maximum level You can dim the lighting to the required level by keeping the key pressed Fan level...

Страница 9: ...ess the Int key while the hood is running at fan level 1 2 or 3 the electronic control will switch back automatically to the previously selected fan level after 5 minutes see Fig 7 If you would like t...

Страница 10: ...f time for all levels is ten minu tes After these ten minutes the ventilation switches off but the lighting stays on Interval ventilation Interval ventilation is a special feature of this appliance wh...

Страница 11: ...s out of the holder repeat the operation for the other grease filters You can clean the stainless steel grease filters in a dishwasher at a maximum temperature of 65 C where it should be supported ver...

Страница 12: ...al filter must be replaced approximately once a year If no activated charcoal filter is installed kitchen smells will not be eliminated The activated charcoal filter KF 001 010 is available through yo...

Страница 13: ...tampering will render all warranty claims null and void Lamp replacement Caution disconnect the power supply before replacing lamps switch off the fuse Caution lamps may still be hot shortly after use...

Страница 14: ...e from the cooking surface to the bottom edge of the extractor hood is 600 mm for electrical appliances The minimum distance from the bottom edge of the pot stand to the bottom edge of the extractor h...

Страница 15: ...essible after installation The duct units listed below are available depending on the height of the ceiling Installation accessories for exhaust air mode Stainless steel design ventilation duct AD 010...

Страница 16: ...can only be used in exhaust air mode The exhaust air is conveyed upwards through an externally attached fan via a ventilation shaft or directly into the open air through the outer wall The extraction...

Страница 17: ...t the minimum distance between the hob and the extractor hood is maintained 600 mm for an electric hob and 650 mm for a gas hob Circulating air mode only there are four brackets which fix the circulat...

Страница 18: ...screws to the ceiling Circulating air mode only assemble the circulating air switch module and fix it to support frame Fig 22 and 23 Cut the flexible air pipe to the required length and fix it to the...

Страница 19: ...hich has no magnetic strips with 2 screws on the top of the support frame Fig 26 14 The second top chimney duct which has magnetic strips should be slightly bent open in order to slide over the first...

Страница 20: ...Gaggenau Hausger te GmbH Carl Wery Stra e 34 D 81739 M nchen www gaggenau com 9000232720 EB 8701 en...

Отзывы: