14
Installation
5.
5.
5.
5.
5. Position the ceiling frame on
the ceiling as shown in Fig. 15
and mark the holes on the wall.
Also drill the securing holes (8
mm (
5
/
16
“) diameter drill bit)
and then fit dowels in them.
6 .
6 .
6 .
6 .
6 .
In the top securing holes of
the drilling template, fix 2
hooks A
A
A
A
A with screws (5 x 45
mm) (Fig. 17).
7.
7.
7.
7.
7. The wall extractor can then be
hooked in. Adjust the unit with
the screws B
B
B
B
B and D
D
D
D
D (Fig. 17).
8.
8.
8.
8.
8. The two bottom screws C
C
C
C
C (5 x 45
mm) can be screwed into the
bottom securing holes in the
housing interior, each with a
shim (Fig. 17). This protects the
extractor against levering out.
9.
9.
9.
9.
9. Make wiring (Fig. 18):
W
W
W
W
WARNING:
ARNING:
ARNING:
ARNING:
ARNING: Turn OFF power
circuit at the service panel
before wiring this unit.
- a circuit of 120V AC, 15 or 20
AMP is required.
- Remove the cover of the
Junction box (situated close to
the body of the motor
housing) and install a 1/2“
conduit connector on it.
- run 3 wires black, white and
green (#16AWG) in 1/2“
conduit from service panel to
junction box.
- Connect black wire from
service panel to black or red
in junction box, white to white
and green to green-yellow.
- Close junction box cover.
Fig
Fig
Fig
Fig
Fig..... 17
17
17
17
17
A
A
D
C
B
Fig
Fig
Fig
Fig
Fig..... 17
17
17
17
17
Fig
Fig
Fig
Fig
Fig..... 18
18
18
18
18