Technical Information
Specifications
Overall Dimensions
MT-4012-10 Base Unit
36.00" x 13.00" x 12.00" ( 914mm x 330mm x 304mm)
MT-4024-10 Base Unit
47.00" x 13.00" x 12.00" (1194mm x 330mm x 304mm)
MT-4036-10 Base Unit
58.00" x 13.00" x 12.00" (1473mm x 330mm x 304mm)
MT-4048-10 Base Unit
69.00" x 13.00" x 12.00" (1752mm x 330mm x 304mm)
CPU with monitor
24.00” x 18.00” x 16.00” ( 130mm x 457mm x 406mm)
Weights
MT-4012E Base Unit
121.0 lbs. (55.0 kg)
MT-4024E Base Unit
152.0 lbs. (69.0 kg)
MT-4036E Base Unit
184.0 lbs. (83.6 kg)
MT-4048E Base Unit
215.0 lbs. (97.7 kg)
CPU with monitor
22.0 lbs. (10.0 kg)
Voltage Requirements (all models)
CPU
110 volts, 110/220 volts or 220 volts AC, 50-60 Hz
Gage Accuracy (at 68 F / 20 C)
*
X Axis
Y Axis
With Summing
**
MT-4012-10
±.00002"
±.00005"
±.00007"
MT-4024-10
±.00002"
±.00010"
±.00012"
MT-4036-10
±.00002"
±.00015"
±.00017"
MT-4048-10
±.00002"
±.00020"
±.00022"
Resolution of internal scale
±.00001"
±.00004"
N/A
Repeatability of assembled MIC TRAC
±.00004"
±.00004"
N/A
Resolution of MIC TRAC CPU
±.00001"
±.00001”
N/A
*
Base units are segmentally linear error corrected.
**
Summing is a software feature that allows the movement of both X and Y to be read together
Service Temperature Range
32° to 100° F (0° to 40° C)
The recommended temperature for any precision metrology, if a high degree of accuracy is
required, is 68 F. All certifications should be made at 68 F.
Содержание MIC TRAC MT-4000
Страница 1: ...M MI IC C T TR RA AC C M MT T 4 40 00 00 0 OPERATION MANUAL ...
Страница 4: ...M MI IC C T TR RA AC C M MT T 4 40 00 00 0 O Op pe er ra at ti io on n M Ma an nu ua al l 4 ...
Страница 6: ...M MI IC C T TR RA AC C M MT T 4 40 00 00 0 O Op pe er ra at ti io on n M Ma an nu ua al l 6 ...
Страница 14: ...M MI IC C T TR RA AC C M MT T 4 40 00 00 0 O Op pe er ra at ti io on n M Ma an nu ua al l 14 ...