FIRST AID MEASURES 

 

Eye: 

No specific first aid measures are required. As a precaution, remove contact lenses, if worn, and flush eyes with water. 

Skin: 

No specific first aid measures are required. As a precaution, remove clothing and shoes if contaminated. To remove 

the material from skin, use soap and water. Discard contaminated clothing and shoes or thoroughly clean before reuse. 

Ingestion: 

No specific first aid measures are required. Do not induce vomiting. As a precaution, get medical advice. 

Inhalation: 

No specific first aid measures are required. If exposed to excessive levels of material in the air, move the 

exposed person to fresh air. Get medical attention if coughing or respiratory discomfort occurs. 

Note to Physicians: 

In an accident involving high-pressure equipment, this product may be injected under the skin. Such 

an accident may result in a small, sometimes bloodless, puncture wound. However, because of its driving force, material 
injected into a fingertip can be deposited into the palm of the hand. Within 24 hours, there is usually a great deal of 
swelling, discoloration, and intense throbbing pain. Immediate treatment at a surgical emergency center is recommended. 

 

FIRE 

 

Leaks/ruptures in high pressure system using materials of this type can create a fire hazard when in the vicinity of ignition 
sources (eg. open flame, pilot lights, sparks, or electric arcs). 

 

FLAMMABLE PROPERTIES: 
Flashpoint: 

(Cleveland Open Cup) 178 °C (352 °F) Minimum 

 

EXTINGUISHING MEDIA: 

Use water fog, foam, dry chemical or carbon dioxide (CO2) to extinguish flames. 

 

PROTECTION OF FIRE FIGHTERS: 
Fire Fighting Instructions: 

This material will burn although it is not easily ignited. See Section 7 for proper handling and 

storage. For fires involving this material, do not enter any enclosed or confined fire space without proper protective equipment, 
including self-contained breathing apparatus. 

Combustion Products: 

Highly dependent on combustion conditions. A complex mixture of airborne solids, liquids, and 

gases including carbon monoxide, carbon dioxide, and unidentified organic compounds will be evolved when this material 
undergoes combustion. 

 

ACCIDENTAL RELEASE MEASURES 

 

Protective Measures: 

Eliminate all sources of ignition in vicinity of spilled material.  

Spill Management: 

Stop the source of the release if you can do it without risk. Contain release to prevent further 

contamination of soil, surface water or groundwater. Clean up spill as soon as possible. Use appropriate techniques such 
as applying non-combustible absorbent materials or pumping. Where feasible and appropriate, remove contaminated soil. 
Place contaminated materials in disposable containers and dispose of in a manner consistent with applicable regulations. 

 

ECOLOGICAL INFORMATION 

 

Waste disposal: 

In accordance with all environmental regulations applicable to your area.

 

 

Spillage: 

Prevent entry into drains, sewers and water course. Soak up with diatomaceous earth or other inert material. 

Store in appropriate container for disposal. 

 

Ecotoxocity: 

This material is expected to be harmful to aquatic organisms and may cause long-term adverse effects in 

the aquatic environment. The ecotoxicity hazard is based on an evaluation of data for the components or a similar material. 
 

HANDLING 

 

Precautionary Measures: 

DO NOT USE IN HIGH PRESSURE SYSTEMS in the vicinity of flames, sparks and hot 

surfaces. Use only in well ventilated areas. Keep container closed. Keep out of the reach of children.

 

General Handling Information: 

Avoid contaminating soil or releasing this material into sewage and drainage systems and 

bodies of water.

 

Static Hazard: 

Electrostatic charge may accumulate and create a hazardous condition when handling this material. To 

minimize this hazard, bonding and grounding may be necessary but may not, by themselves, be sufficient. Review all 
operations which have the potential of generating and accumulating an electrostatic charge and/or a flammable atmosphere 
(including tank and container filling, splash filling, tank cleaning, sampling, gauging, switch loading, filtering, mixing, 
agitation, and vacuum truck operations) and use appropriate mitigating procedures. 

 

 

DISPOSAL CONSIDERATIONS

 

Use material for its intended purpose or recycle if possible. Oil collection services are available for used oil recycling or 
disposal. Place contaminated materials in containers and dispose of in a manner consistent with applicable regulations

 
 

DEXRON® III OIL SAFETY DATA

 

Содержание GB715

Страница 1: ... TOOL GAGE BILT MADE IN U S A GAGE BILT Inc 44766 Centre Court 586 226 1500 Clinton Twp MI 48038 586 226 1505 Fax e mail solutions gagebilt com www gagebilt com GAGE BILT TOOLS ARE AVAILABLE WORLDWIDE E MAIL US FOR A DISTRIBUTOR NEAR YOU S N 1242 AND ABOVE PLEASE CONTACT GAGE BILT FOR ALL OTHER SERIAL NUMBERS ...

Страница 2: ... Technical Specifications 3 Description of Functions 4 Safety Warnings 5 Principle of Operation 6 How to Setup the GB715 7 How to use the GB715 8 Maintenance 9 Filling and Bleeding 10 Troubleshooting 11 Overhaul 12 Disassembly and Parts Lists 13 14 DEXRON III Oil Safety Data 15 Nose Assembly Selection Chart 16 EU Conformity and Warranty 17 ...

Страница 3: ...80 lbs 1 7 kg and can be operated in any position with one hand It has a 1 200 30 5 mm rivet setting stroke and a rated pull load of 1400 lbs 6 2 kN with 90 psi 6 2 bar air pressure at the air inlet The GB715 riveter operates on 90 to 100 psi 6 2 6 9 bar Max providing the maximum efficiency At 90 psi 6 2 bar air pressure the GB715 does not exceed 81 5 dB A and consumes 3 cfm at 20 cycles a minute ...

Страница 4: ...REV 2 16 4 GB715 S N 1242 AND ABOVE PLEASE CONTACT GAGE BILT FOR ALL OTHER SERIAL NUMBERS DESCRIPTION OF FUNCTIONS Air Inlet Actuator Handle Head Cylinder ...

Страница 5: ...case of interruption of energy supply 6 Use only lubricants recommended by the manufacturer 7 Avoid unsuitable postures as it is likely for these positions not to allow counteracting of normal or unexpected movement of the tool 8 If the tool is fixed to a suspension device make sure that fixation is secure 9 Beware of the risk of crushing or pinching if nose equipment is not fitted 10 Due to the t...

Страница 6: ...of the head cylinder assy causing the piston to move to the rear of the head cylinder assy The internal components of the attached nose assembly are also moving with the piston to start the fastener installation When the fastener installation is completed the actuator lever assy is released Air pressure is then built up inside of the handle assy causing the valve spool assy to return to its origin...

Страница 7: ...uired that eye protection and hearing protection be worn during operation WARNING The users or the user s employer should assess specific risks that could be present as a result after each use based on their application Be sure there is adequate clearance for tool and operator s hands before proceeding Keep fingers clear of any moving parts Keep fingers clear from fasteners and installed materials...

Страница 8: ...ould be present as a result after each use based on their application Be sure there is adequate clearance for tool and operator s hands before proceeding Keep fingers clear of any moving parts Keep fingers clear from fasteners and installed materials Severe personal injury may result Verify that hydraulic hose fittings and couplings air and electrical connections are secure Verify the airlines and...

Страница 9: ...nd cautions WARNING Disconnect tool from its power source before performing maintenance cleaning or when replacing worn or damaged components Severe personal injury may occur if power source is not disconnected WARNING Read SDS documents for all applicable materials The performance of any tool depends upon good maintenance practices Following these minimal requirements daily will extend the life o...

Страница 10: ...y 704153 Install button head cap screw 402482 and stat o seal S572 on head cylinder assy 715110 and torque to 35 40 inch lbs Reconnect air and cycle tool five more times 7 Check tool stroke of 1 200 min 30 5 mm We recommend using dial calipers With the actuator lever assy released 704343 check dimension A While holding actuator lever assy 704343 in check dimension B Add dimension B to dimension A ...

Страница 11: ...y be blocked or damaged Hole diameter should be 028 Clear and size or replace 3 NO OPERATION WHEN ACTUATOR LEVER ASSY 704343 IS DEPRESSED a Tool seized due to mechanical failure or damaged parts 4 OIL LEAKAGE a DO NOT OPERATE WITH OIL LEAKING FROM TOOL HIGH PRESSURE OIL MAY CAUSE SEVERE PERSONAL INJURY b Any oil leaking externally should be traced to its source An o ring or seal that leaks should ...

Страница 12: ... WARNING Personnel must read and understand all warnings and cautions WARNING Tool must be maintained in a safe working condition at all times and examined on a daily basis for damage or wear Any repair should be done by qualified personnel trained on Gage Bilt procedures WARNING Disconnect tool from its power source before performing overhaul Severe personal injury may occur if power source is no...

Страница 13: ...704118 to 45 foot lbs 2 Attach the seal guide 704152 to the piston rod assy 704138 and tap the piston rod assy 704138 through the packing plug 704118 3 Attach air piston assy 704121 and flexlock nut 400559 Torque flexlock nut to 40 inch lbs 4 Attach air piston assy 704121 to piston rod assy 704138 5 With the piston rod in the down position fill oil passage on top of handle assy 704132 with automat...

Страница 14: ...REV 2 16 14 GB715 S N 1242 AND ABOVE PLEASE CONTACT GAGE BILT FOR ALL OTHER SERIAL NUMBERS PARTS LIST ...

Страница 15: ...ds will be evolved when this material undergoes combustion ACCIDENTAL RELEASE MEASURES Protective Measures Eliminate all sources of ignition in vicinity of spilled material Spill Management Stop the source of the release if you can do it without risk Contain release to prevent further contamination of soil surface water or groundwater Clean up spill as soon as possible Use appropriate techniques s...

Страница 16: ...S THE GB715 WILL INSTALL THE ABOVE FASTENERS CHERRYMAX CHERRYMAX AB MBC LOCK CREATOR BACR15FR FP BACR15GF GK NAS1900 S U SERIES BLIND RIVET WITH DRIVE WASHER GROUND STUD 1 8 5 323 3 163 ALL COUNTERSUNK C NOSE ASSEMBLIES MAY USED TO INSTALL BOTH UNIVERSAL AND COUNTERSUNK HEAD RIVETS CHERRYM AX AND M BC ARE REGISTERED TRADEM ARKS OF CHERRY AEROSPACE FASTENERS FASTACK AND SUPERTACK ARE REGISTERED TRA...

Страница 17: ... no circumstances will the seller be liable for incidental or consequential damages or for damages incurred by the buyer or subsequent user in repairing or replacing defective goods or if the goods covered by this warranty are reworked or subjected to any type of additional processing This warranty is void if Seller is not notified in writing of any rejections or defects within 6 months after the ...

Отзывы: