12
Rev. 3/22
GB713SH INSTALLATION TOOL S/N: 1135 AND ABOVE
PLEASE CONTACT GAGE BILT FOR ALL OTHER SERIAL NUMBERS.
1.
Stand handle assembly (744129) on floor, stretch hose and head assembly upward and lay flat on a table or bench. When bleeding
tool always keep the head assembly higher than the handle assembly (744129).
2.
Remove button head cap screw (402482) and stat
-
o
-
seal (S572) from manifold
-
handle (744303) hole marked #3 on the side of
the manifold
-
handle (744303). Attach air bleeder assembly (704153) to manifold
-
handle (744303) hole marked #3 in an upright position.
3.
Connect the tool to air supply and cycle tool ten times holding the lever (704345) down for 2
-
3 seconds between cycles to remove
any air from the tool.
4.
Disconnect air supply. Remove air bleeder assembly (704153) from manifold
-
handle (744303) and replace with button head cap
screw (402482) and stat
-
o
-
seal (S572) and torque 35
-
40 inch lbs. (3.95
-
4.52 Nm). Do not over tighten.
5.
Remove button head cap screw (402482) and stat
-
o
-
seal (S572) from head cylinder assembly (713123) and attach air bleeder
assembly (704153) in an upright position.
6.
Connect air supply. Cycle tool ten times removing any air bubbles.
7.
Disconnect air supply. Remove air bleeder assembly (704153) and replace button head cap screw (402482) and stat
-
o
-
seal (S572)
on the head cylinder assembly (713123) and torque 35
-
40 inch lbs. (3.95
-
4.52 Nm). Do not over tighten.
8.
Connect air supply. Cycle tool ten times and check stroke of
.760” (19.3
mm) using steps a thru c below. (Also see diagram below).
We recommend using dial calipers.
a. With the lever (704345) released, check dimension (A).
b. Holding lever (704345), check dimension (B).
c. Subtract dimension (A) from dimension (B). If stroke is not consistent within 1/64" (.396 mm) repeat bleeding procedure
until stroke met.
Gage Bilt offers a depth gage (Pt.# A
-
1935) to help simplify and more accurately check your tool stroke. Please contact Gage Bilt
for more information.
BLEEDING PROCEDURE:
WARNING:
Do not cycle tool without air bleeder assembly (704153), or the screw and stat
-
o
-
seal, installed in tool head. Severe
personal injury could result.
WARNING:
Use CAUTION when removing screws, air bleeder assembly (704153) and fill bottle (745263). Hydraulic oil may be
under pressure.
CAUTION:
Before filling handle assembly (744129), air piston assembly (744121) must be all the way down.
CAUTION:
When forcing piston rod assembly (744136) downward, with head cylinder assembly (713123) removed, hydraulic oil will eject
forcibly from handle assembly (744129).
CAUTION:
When bleeding tool, ensure tubing is free from kinks or other obstructions.
* FILLING & BLEEDING VIDEO AVAILABLE AT:
http://www.gagebilt.com/rivet_tools_videos.php
Bleeder hole on head cylinder assembly (713123)
*located on far side*
Hole marked
“3”
on side of
Manifold
-
Handle (744303)
Images may not reflect actual tool.
Air Bleeder
Assembly
(704153)
Note:
•
Air Bleeder Assembly (704153) (sold separately) is required.