ENGLISH
13
Performing regular maintenance according to the Manufacturer's instructions improves
performance and extends the working life of the machine.
When cleaning the machine, respect the following:
•
Avoid the use of water cleaners. Water could penetrate the electrical compartment or
motors leading to damage or the risk of short circuit;
•
Do not use steam to avoid the heat warping plastic parts;
•
Do not use hydrocarbons or solvents as they could damage the cowling and rubber
parts.
8.2.
Replacing/mounting the centre brush
!
DANGER
This operation must be performed with the machine off and ignition key removed.
Proceed as follows:
•
Open the door on the left of the machine by unscrewing the knob (fig. E).
•
Unscrew and remove the three knobs fixing the brush compartment cover (fig. F).
•
Remove the brush compartment cover (fig. F).
•
Remove the brush (fig. F).
•
Remove the adaptor from the brush drum and place it on the new brush, maintaining
the same bristle slant (fig. G).
•
Proceed with the same sequence in reverse to replace the brush.
8.3.
Replacing/adjusting the side brushes
!
DANGER
This operation must be performed with the machine off and ignition key removed.
To facilitate transport, the side brush/es is/are not mounted in the operating position.
To mount the side brush in the correct position, proceed as follows:
•
Remove the side brush retainer screw from the motor shaft (fig. H).
•
Remove the adhesive tape fixing the drive key to the motor shaft.
•
Position the brush complete with flange on the shaft (fig. H).
•
Fix the brush in position using the retainer screw removed at point 1 (fig. H).
To replace worn side brushes, repeat the procedure above.
8.4.
Replacing/installing the suction filter.
!
DANGER
This operation must be performed with the machine off and ignition key removed.
Every 50 working hours or as necessary, check the suction filter as follows:
•
Pull lever (fig. B, ref. 5) that locks/releases, then take out the cover(fig. B, ref. 2).
•
Unscrew the four screws (fig. I).
•
Disconnect the connector on the filter shaker (fig. I).
•
Remove the filter from its housing (fig. I).
•
Thoroughly clean the filter with a vacuum cleaner or replace it (fig. J).
•
To mount the filter, follow the same procedure in reverse.
•
Close the cover (fig. B, ref. 2) and lock the cover by lever (fig. B, ref. 5) .
8.5.
Circuit breaker – reset
IMPORTANT
This operation must be performed with the machine off and ignition key removed.
Содержание GTS 1250