7
hours
)
STEP 3: ANALYSE
(Check if the battery voltage reaches to the threshold
after desulphation, and charging begins if the battery voltage is OK)
STEP 4: SOFT START
(Charge with echelon constant current)
STEP 5: BULK
(Charge with constant maximum current until battery
voltage is reached to the threshold)
STEP 6: ABSORPTION
(Provide gradually declining current charge for
maximum battery voltage)
STEP 7: ANALYSE
(Test if the battery can hold charge)
STEP 8: MAINTENANCE
(Continuously monitor the battery, and charging
current will intelligently adapt to the variable battery voltage)
BATTERY LEVEL INDICATOR
LED
Explanation
25%
The 25% Charge Red LED will slowly flash when the
battery level is less than 25%. When 25% is reached,
the LED will be solid.
50%
The 50% Charge Red LED will slowly flash when the
battery level is less than 50%. When 50% is reached,
the LED will be solid.
75%
The 75% Charge Red LED will slowly flash when the
battery level is less than 75%. When 75% is reached,
the LED will be solid.
100%
The 100% Charge Green LED will slowly flash when
the battery level is less than 100%. When 100% is
reached, the 100% Charge LED will be solid. The
25%, 50% and 75% Charge LEDs will turn off.