19
SELECTOR “O” , “P”, “I”.
Position “0” : The heater is switched off permanently. The display is switched off.
Position “P” : The heater is following a program. It will maintain the SUN, MOON or
temperatures as per
the introduced program. At this position if the display shows the time the heater is frost protection
mode.
Position “I” : The heater is maintaining the SUN temperature constantly both luminous indicators SUN and
MOON will be lit. This could be useful when SUN temperature is required and we do not want to
modify the program. At this position if the display shows the time the heater is in frost protection
mode. Press the
key to shift from frost protection mode (time is shown in the display) to
standard mode (temperature is shown in the display) and vice versa.
SUN, MOON AND
TEMPERATURES
The electronic programmer is able to handle three temperature levels during the 24h of the day. Press the
key to set the SUN temperature. The display will show the SUN temperature value blinking.
Set the SUN temperature value by means of the
+
o
–
keys and press the key to store the value. If the
display shows the time the heater is in frost protection mode. Press the
key to shift from frost protection
mode (time is shown in the display) to standard mode (temperature is shown in the display) and vice versa.
Repeat the above steps with the key to set the MOON temperature. The
temperature level is 3ºC and
it is a fix value. This temperature level can be used as off selection when setting the temperatures during
certain times of the day.
SUN, MOON, or
temperatures can be allocated to any of the 48 intervals of 30 minutes of the day.
DAILY PROGRAMMES
It is basic to visualize the day split into 48 intervals of 30 minutes each; SUN, MOON, or
temperatures
can be allocated to any of them.
The default settings include daily mode so that the heater will repeat the program every day. If different
programmes are required along a week, please see the next step WEEKLY PROGRAMMES. To check a
programme or to make a new one follow these steps:
Press the
PRG
key and the display will show
00:00
intermittently. Press one of the three keys
to allocate SUN, MOON or OFF (frost protection) from 00:00h to 00:30h. If SUN or MOON temperatures
are selected the relevant luminous indicator will be lit. If OFF temperature
is selected both luminous
indicators will be off.
Press the
+
key to go to the next interval. The display will show
00:30
intermittently and, again, press one of
the three keys
to allocate SUN, MOON or OFF (frost protection) from 00:30h to 01:00h or
press
+
key directly if the existing temperature level is ok.
Repeat these steps allocating the desired temperatures levels over the 24 hours of the day. Press the
–
key at
any time to modify a previous period. By reaching the
23:30
in the display and pressing
+
key the
controller will store the program and will return to the previous mode. At any time
PRG
key can be use
also to store the program and return the previous mode.