8
3.5. OPERATION MODE:
The HHR operates in weekly programming mode. The temperature level (ECO, Frost protection and Comfort) can be set for
each period of time (30’
minutes) in the different days in the week.
Storage heater resistances will operate during off peak rate in order to charge the heater according to the demand of the room.
A fan is used to discharge the heating core if necessary to reach the current set point temperature. A balance resistance can
operate promptly during on peak periods providing additional heating to the room if necessary. The maximum working period of
the balance resistance can be adjusted and cancelled by modifying P06 parameter. (p
lease go to “General Settings”).
WEEKLY PROGRAMMING AND TEMPERATURE LEVEL
In HHR, the set point temperature varies according to the weekly schedule established by the user. The temperature level (Frost
protection, ECO and Comfort) for each time interval (30 minutes) can be selected to adjust the temperature in the room to the
habits and needs of the different users.
Temperature Level
Three different temperature level can be set for each time interval. The value of the temperature level can be modified by the
user.
-
COMFORT
: It is recommended for the periods of time when the user is at home and the maximum comfort is
required. Default
-
ECONOMIC
: It is recommended for nights and small away periods of time. Default value 18ºC.
-
FROST PROTECTION
: It is recommended for long away periods of time. Default value 3ºC. The value of
frost protection temperature can´t be modified.
To modify the set point temperature of Comfort and Economic temperature level, press the appropriate
or
key,
Words
“Sun” or “Moon” will appear for one second and then, the temperature value
will be displayed blinking. Adjust the value
for the temperature level using and key and confirm and save it by pressing the appropriate
or
key.
If any key is pressed in 10 seconds, the display returns to main screen and changes are not saved.
Weekly programming
To modify the program, press the
key (“
+
” & “
Moon
”). The text “
Prog
” is displayed for 1
second and then, the Day 1 is
displayed blinking. Select the day to modify using the and keys.
Use the
key to enter the program of the displayed day. The first-time interval is displayed alternating with the temperature
level. To modify the temperature level for the displayed interval:
-
Press
to set
Economic temperature
level for the current time interval.
-
Press
to set
Comfort temperature
level for the current time interval.
-
Hold
for 3 seconds to set
Frost Protection temperature
level for the current time interval.
Use and keys to navigate among the different time interval in the day. By pressing key when the last time
interval is displayed (23:30), the day of the week is displayed, and the others day can be modified.
It is possible to copy the program of a day in the next one. Hold the key when the day to copy is displayed, the text
CPXY
(X: day copied, Y: new copy) will be displayed to confirm the copy.
Press the key when the last day of the week is displayed (Day 7) to save the settings and exit to the main screen.
By default, all time intervals are in Frost Protection Temperature level.