MECHANICAL SPECIFICATIONS:
Size
:
18.1x
13.2
x
16
inch
RF Connectors
: N-Type Female
Weight :
65
Lb.
(28.5
kg)
approx.
ENVIRONMENTAL CONDITIONS:
The unit is designed for indoor applications:
Operating temperature: - 20
°
C to + 50
°
C
Storage temperature: - 50
°
C to + 90
°
C
FCC NOTE:
The product has been tested and found to comply with the Federal Communications
Commission (FCC) RF Exposure Requirements, pursuant to FCC Part 22 and 24.
IC NOTE:
The product has been tested and found to comply with the Industry Canada (IC) RF
Exposure Requirements, pursuant to IC RSS-131.
NOTE:
The Manufacturer’s rated output power of this equipment is for single carrier
operation. For situations when multiple carrier signals are present, the rating would
have to be reduced by 3.5 dB, especially where the output signal is re-radiated and
can cause interference to adjacent band users. This power reduction is to be by
means of input power or gain reduction and not by an attenuator at the output of the
device.
RF EXPOSURE WARNING:
In order to comply with the FCC RF exposure requirements, the BDA-CELLAB/PCSF-
33/33-80-OCMG antenna installation must comply with the following:
Yagi type or similar directional antenna must be installed so as to provide a
minimum
separation distance of 60 cm (~ 24 inches) between the antenna and persons within
the area. (This assumes an antenna with gain of 11 dBi, VSWR
≤
1.5:1, Zo= 50 ohms)
The Omni directional (or leaky cable ) must be installed so as to provide a
minimum
separation distance of at least 25 cm (~10 inches) between the indoor antenna
connected to the RF booster and the human user’s body within the area. (This
assumes an antenna with gain of 0-2 dBi, VSWR
≤
2:1, Zo= 50 ohms).