Trouble Shooting
Door Multi-point Locking System І Automatic Smart Access Controlled
If using a SECURE connect 200, follow the steps below
to perform a reset of the system:
1. Remove the plastic terminal block next to V4/93/92/91
on SC200R to reveal reset terminals
2. Bridge reset terminals with an aligator clip
3. Turn the power supply off and on again, and leave the aligator clip
for 3 seconds before removing it
If still not working, go to step 4
4. Remove the plastic terminal block next to V4/I2/V4/I1
on SC200F to reveal reset terminals
5. Bridge reset terminals with an aligator clip
6. Put the SC200F tappet contacts in connexion with the SC200R
7. Turn the power supply off and on again, and leave the aligator clip
for 3 seconds before removing it
* SECURE connect components will flash green/red to indicate a repairing process