Information in this document can be modified without notice.
Edition 07.2020
03.5.13
03
5
Door Multipoint Locking System
Solid brass handle & 45mm plate series
Assembly and Operating Instructions
A-opener, SECUREconnect 200, Fingerprint Scanner or Code Keypad
– Door Leaf Mounted Connection Diagram
Attention:
Only 24V DC voltage sources in accordance
with EN 60950 may be used.
Connecting cable
Signal
GND (minus)
Grey (blue)
Brown
24 V (plus)
Black
Control line
Connecting cable
Signal
Yellow
GND (minus)
White
RS-485 A
Green
RS-485 B
Brown
24 V (plus)
Stabilized power supply
110V AC / 24V DC, 1.3A
Switch control (optional)
Fingerprint
scanner or
code keypad
Cable routing of module (leaf-side)
Please use the enclosed system cable to connect the module.
The SECUREconnect and the access control module communicate
via an encoded bus.
Connection terminals of SECUREconnect 200R (frame-side)
The terminals V42 and G42 are provided for the connection of an external
24V DC voltage supply to operate SECUREconnect 200.
SECUREconnect 200F
SECUREconnect 200R
GS
VS
90
GS
96
95
94
Door Multi-point Locking System І Automatic Smart Access Controlled