11
3
Test Mode
3.1
How to Enter Test Mode
Turn the power on while pressing "
ZERO
" Key to enter Test Mode with “
TEST
” being
displayed on the display.
3.2
Description of Test Mode
4
Calibration Mode
4.1
How to Enter Calibration Mode
Turn the power on and press "CAL" Key or “ZERO + UNIT + PRINT” Keys together until
show “CAL” on the display to enter the Calibration Mode.
4.2
Description of Calibration Mode
4.2.1
Maximum Weight Setting (select model)
: It allows to select the maximum weight. Press “
” Key while “
CAL
” is shown on the
display to display the current maximum weight.
Use below Keys to change the maximum weight.
-
UNIT
Key: Use to change the maximum weight.
-
Key: Use to save a newly set maximum weight and return to the previous page.
Test Type
Description
A/D Test
Don’t press any Key to show the current A/D value on the display.
Communication
Test
Press "
TARE
" Key to show “Serial test ok” on the display via serial
communication.
Backlight Test
Press "
UNIT
" Key to change backlight brightness and show the value
of brightness levels.
Count Value Test
Press "
" Key to show count value on the display. Press “
ZERO
” Key while
the count value is displayed to adjust the count value.
Содержание GL-6000L Series
Страница 2: ...2 ...
Страница 5: ...5 ...
Страница 6: ...6 ...
Страница 8: ...8 2 2 Product Size ...
Страница 22: ...22 9 How to Download Program 9 1 Downloader Connection ...
Страница 23: ...23 9 2 How to Download STEP1 Initiate HOPE3000FOR8051 program STEP2 Click File Open and Download ...
Страница 24: ...24 STEP3 Choose hex file STEP4 Select HT85F2280 and click 0K ...
Страница 25: ...25 STEP5 Choose ICP e C0N12C and click OK STEP6 Click Smart Programming ...
Страница 29: ...29 11 How to Sealing ...
Страница 30: ...30 12 GL6000L Series MS EXPLODED ...
Страница 31: ...31 ...
Страница 33: ...33 MEMO ...
Страница 34: ...34 MEMO ...
Страница 35: ...35 MEMO ...