User configurable parameters can be programmed using the 4-position DIP switch, the on-board push-button next 
to the DIP switch, and on-board LED.  
 

Enter Programming Mode 

Press the Program button. The LED will begin flashing the option code of the selected parameter. 

Select Parameter  

Select the parameter you wish to view or program using the DIP switch. (the white square indicates position of the 
switch; e.g. for parameter 0, all switches are in the down or off position. 

View Current Option Code 

The LED will repeatedly flash the option code for the currently selected parameter; e.g. two flashes followed by a 
pause indicates option 2. 

Change the Option Code 

Momentarily press the push-button during the pause to advance the option to the next higher number, until you 
get the desired number of flashes. 

Save the Option Code 

During the pause between code flashes, press and hold down the Program button for about 4 seconds until the 
LED starts flashing rapidly, which indicates the save is complete. 
 

Select the next Parameter 

Repeat the above as needed to view or make changes to other parameters using the DIP switch to select.  
 

Exit Programming Mode 

Turn off power. The new settings will take effect at next power up. 

All Purpose Train Control 

User Programming 

 
 
 
Option 

 
Parameter 5 -  
Speed Pot 
Momentum 

Fastest Response 

Fast 

Medium 

Slow 

Slowest Response 

Factory settings 

The  number  of  LED  flashes  indicates  the 
Option Number for the Parameter selected 
by the DIP switch. 

 

 
 
 
Option 

 
Parameter 0 -  
Accel/Decel 
Rate 

Fastest 

Fast 

Medium 

Slow 

Slowest 

 
 
 
Option 

 
Parameter 1 -  
Station Stop 
Time 

5   Secs 

10 Secs 

15 Secs 

20 Secs 

 
 
 
Option 

 
 
Parameter 3 -  
Run Mode 

1 Min Time Out 

2 Mins Time Out 

5 Mins Time Out 

10 Mins Time Out 

Continuous Running 

One Lap & Stop  
(At least one Reed Switch Re-
quired) 

 
 
 
Option 

 
Parameter 4 -  
Auto Start 
Interval Timer 

Disabled 

15 Mins 

20 Mins 

30 Mins 

60 Mins 

 
 
 
Option 

 
Parameter 2 -  
Station Stop 
Percentage 

100% 

75% 

50% 

25% 

0% - Disabled 

Back ‘n Forth Trolley Mode 
(Two Reed switches Required) 

1

2

3

4

ON

1

2

3

4

ON

1

2

3

4

ON

1

2

3

4

ON

1

2

3

4

ON

1

2

3

4

ON

Содержание APTC

Страница 1: ...ision C Updated 8 18 2021 Operation and Installation Manual G Scale Graphics 5860 Crooked Stick Dr Windsor CO 80550 970 581 3567 GScaleGraphics comcast net www GScaleGraphics net Revision A Updated 8...

Страница 2: ...rolley line Use the Max Speed feature to limit speed when children are at the controls Manual speed control with user programmable momentum Automated Random Station Stops via track mounted reed switch...

Страница 3: ...of the Speed Pot Emergency Stop Holding the Stop button or contact closure for more than 1 2 second at any time will initiate a quick stop Speed Pot Adjust the speed pot at any time to change the spe...

Страница 4: ...each end of a track and Parameter 2 Option 6 it will run in back and forth trolley mode Stopping the train A running train can be stopped automatically after running for One Lap or after a Time Perio...

Страница 5: ...when the track switch is activated by a magnet The green APTC LED will blink OFF whenever a start or stop command is received whether it is hardwired or wireless The red LED on the APTC wireless rece...

Страница 6: ...rack Reed Switch Remote Start Switch Start Com Start SS 5V from APTC Com Com Stop T T Power Supply 7 25 VDC In To Track 10 Amps Max All Purpose Train Control Wiring Diagram Wireless Track Reed Switch...

Страница 7: ...t train will leave the station make one lap returning to the station Option 5 can be used for Continuous Running no time out Parameter 4 Auto Start Interval Timer Sets the amount of time between autom...

Страница 8: ...hing rapidly which indicates the save is complete Select the next Parameter Repeat the above as needed to view or make changes to other parameters using the DIP switch to select Exit Programming Mode...

Страница 9: ...trical Power Input 7 25VDC reverse polarity protection prevents damage but will not operate Track Output Up to 10 amps Short circuit protection PWM Pulse Width Modulation 20 KHZ Control Inputs Normall...

Страница 10: ...e of the power supply for 115 VAC U S Output voltage should be 24 VDC maximum for use with the G Scale Graphics Trackside R C or other Track Throttles But no adjustment should be necessary as received...

Отзывы: