Operation and Installation Manual 

G-Scale Graphics 

5860 Crooked Stick Dr. 

Windsor, CO 80550 

970-581-3567 

 

[email protected] 

www.GScaleGraphics.net 

 

Revision A: Updated 8/18/2021 

Содержание APTC

Страница 1: ...ision C Updated 8 18 2021 Operation and Installation Manual G Scale Graphics 5860 Crooked Stick Dr Windsor CO 80550 970 581 3567 GScaleGraphics comcast net www GScaleGraphics net Revision A Updated 8...

Страница 2: ...rolley line Use the Max Speed feature to limit speed when children are at the controls Manual speed control with user programmable momentum Automated Random Station Stops via track mounted reed switch...

Страница 3: ...of the Speed Pot Emergency Stop Holding the Stop button or contact closure for more than 1 2 second at any time will initiate a quick stop Speed Pot Adjust the speed pot at any time to change the spe...

Страница 4: ...each end of a track and Parameter 2 Option 6 it will run in back and forth trolley mode Stopping the train A running train can be stopped automatically after running for One Lap or after a Time Perio...

Страница 5: ...when the track switch is activated by a magnet The green APTC LED will blink OFF whenever a start or stop command is received whether it is hardwired or wireless The red LED on the APTC wireless rece...

Страница 6: ...rack Reed Switch Remote Start Switch Start Com Start SS 5V from APTC Com Com Stop T T Power Supply 7 25 VDC In To Track 10 Amps Max All Purpose Train Control Wiring Diagram Wireless Track Reed Switch...

Страница 7: ...t train will leave the station make one lap returning to the station Option 5 can be used for Continuous Running no time out Parameter 4 Auto Start Interval Timer Sets the amount of time between autom...

Страница 8: ...hing rapidly which indicates the save is complete Select the next Parameter Repeat the above as needed to view or make changes to other parameters using the DIP switch to select Exit Programming Mode...

Страница 9: ...trical Power Input 7 25VDC reverse polarity protection prevents damage but will not operate Track Output Up to 10 amps Short circuit protection PWM Pulse Width Modulation 20 KHZ Control Inputs Normall...

Страница 10: ...e of the power supply for 115 VAC U S Output voltage should be 24 VDC maximum for use with the G Scale Graphics Trackside R C or other Track Throttles But no adjustment should be necessary as received...