How to use the 2G/3G Portable PIR  Alarm

Once you have positioned the pir sensor, installed the simcard and programmed the
numbers the system is ready to use.

The GSM Portable PIR  Alarm has two modes, alarm mode and auto mode. In alarm
mode you have to arm the alarm manually when required. In auto mode, the alarm is
always armed. You can choose the best mode that suits your requirements.

These modes are selected by sending the text message as follows.

#

mode

=

1

Alarm Mode (default)

#

mode

=

2

Auto Mode

Mode 1 - Alarm Mode: 

#

mode

=

1

#

Alarm mode is the default mode. You will need to set the alarm to ON before it detects
movement and sends an alarm message.

To set the alarm to ON you will need to send the text message

#

ALARM

=

ON

This will activate the alarm.

#

ALARM

=

ON

This will deactivate the alarm.

It is important to remember that when the alarm has been triggered you will need to reset
the alarm by sending another text message 

#

ALARM

=

ON

#

Mode 2 - Auto Mode: 

#

mode

=

2

#

The alarm is always armed and will trigger when movement is detected. It will
automatically reset back into armed mode after 20 seconds of no movement being
detected.

How to use the Relay Output

Dipswitch 2 = OFF 

ref page 3

The Portable PIR  Alarm has a 2 amp relay output which can be used to switch on
external electrical devices such as lighting, sirens etc.

By texting the unit you can turn the relay ON or OFF. Below are examples on how to do
this.

#

REL

=

ON

This will turn the relay output ON

#

REL

=

OFF

This will turn the relay output OFF

After each operation the unit will reply with the text message 

REL ON/OFF

Dipswitch 2 = ON

ref page 3

The relay can also be set to pulse for 20 seconds when the inputs have been triggered. To
activate this mode you need to set DIPSWITCH 2 to the ON position. (Page 3)

This can be used to trigger a siren or reset other equipment.

Содержание 2G RF PIR

Страница 1: ...2G 3G GSM Portable PIR Alarm www gsm activate co uk MODEL RF PORTABLE PIR PAGE 1 ...

Страница 2: ...reezing conditions GSM Module Specification GSM Frequency Quad band freq 850 900 1800 1900 3G Model 2100 Mhz Power Supply Voltage 9 24 volts DC 1 Amp Min Current used in standby mode 60mA Max IP65 Rated Enclosure for outside installation 2 Amp Relay Output Micro 2G or 3G Simcard No landline required Dimensions L100 x W68 x H50mm Dimensions PCB Only L95 x W67mm Sim Active Function Operating Tempera...

Страница 3: ...ICTURE ABOVE Signal Strength To help make sure that you have placed the unit in a suitable position you can text the unit to see how much signal strength the detector is receiving Simply text the unit SIGNAL The detector will perform a test on the signal strength You will receive a text message telling you the signal strength score between 0 up to 30 We strongly recommend that you place the unit w...

Страница 4: ...his as a text to the simcard of the unit with your preferred mobile number for second contact 3 07123456789 Then send this to the simcard of the unit with your preferred mobile number for third contact If you wish to cancel a number follow this example Example HASH 1 2 or 3 EQUALS DELETE HASH Then send this as a text to the simcard number of your unit PLEASE NOTE Please only send one text message ...

Страница 5: ...message Telephone Call Alerts The Portable PIR Alarm can be programmed to send you a telephone call after each text alarm has been has been sent You will receive approximately three ring tones The unit will then hang up automatically This is to prevent call charges being incurred To set the call alerts to ON please send the text message as follows CALL ON The unit will reply back with the text mes...

Страница 6: ...educe the sensitivity 3 Ensure the sensors line of sight is free from false alarm sources such as bushes trees etc Pay attention to these as they may change seasonally 4 It is important to have the correct power supply to operate this device successfully You will need a 12 volt 2 Amp supply or 12 volt battery You can purchase both of these from our website www gsm activate co uk 5 Now you have the...

Страница 7: ...o remember that when the alarm has been triggered you will need to reset the alarm by sending another text message ALARM ON Mode 2 Auto Mode mode 2 The alarm is always armed and will trigger when movement is detected It will automatically reset back into armed mode after 20 seconds of no movement being detected How to use the Relay Output Dipswitch 2 OFF ref page 3 The Portable PIR Alarm has a 2 a...

Страница 8: ...d GSM Detector To connect the wireless sensors you will need to go through a process so that the devices are matched to the receiver on the GSM module 1 Switch ON the GSM module 2 Switch on the beams and allow them to warm up for 15 seconds 3 Hold down the pairing button on the RF Module for 3 seconds refer to page 1 4 Trigger the beams by placing your hand enough to block both of the beams 5 The ...

Страница 9: ...n necessary The GREEN LED will flash 8 times to indicate that reset is complete Dipswitch Settings Dipswitch 1 ON 3G Selected OFF 2G Selected Dipwitch 2 ON Pulse Relay 20 Seconds OFF Relay Off For more technical support please browse the FAQ s on our website www gsm activate co uk Alternatively email our technical support team at technical gsm activate co uk and we will do our best to get back to ...

Отзывы: