5250W Dual Fuel Generator
20
Operation
NOTE: THE PARTS LISTED ABOVE ARE HELPFUL FOR LOCATING THE
CONTROLS MENTIONED BELOW GROUNDING
Before Starting the Generator
CAUTION: PRIOR TO FIRST USING THE GENERATOR, THE ENGINE MUST BE
FILLED WITH HIGH QUALITY SAE 10W-30 GRADE ENGINE OIL. TO DO SO,
UNSCREW AND REMOVE THE ENGINE’S OIL DIPSTICK LOCATED AT THE
BOTTOM OF THE ENGINE CRANKCASE. FILL THE ENGINE CRANKCASE UNTIL
THE OIL LEVEL IS LEVEL WITH THE UPPER MARKED LINE ON THE DIPSTICK.
THEN SCREW THE DIPSTICK BACK INTO THE OIL FILL HOLE.
Filling the Fuel Tank – Follow the steps below
to fill the fuel tank:
1. Check that the engine power switch is in its
“OFF” position.
2. Before the first use, remove the fuel
tank cap and fill the fuel tank with unleaded
gasoline. When fueling, be sure that the
fuel strainer is in place. Replace the fuel
tank cap. Thereafter, check the engine’s
fuel gauge for the amount of unleaded
gasoline in the fuel tank. If necessary,
refill the fuel tank with unleaded gasoline;
the generator must be turned off and
cooled down before refilling the fuel tank.
Connecting the LPG/Propane tank
1.Make sure the generator is off, on a flat surface
in well ventilated area.
2.Make sure propane tank valve is in the off position.
3.Make sure the fuel selector switch to “Propane”.
4.Remove the plastic cover on the generator propane
inlet valve.
5.Use your fingers tighten the LPG hose (included)
end below to the generator propane inlet. DO NOT
OVER-TIGHTEN 35-88 Ib-in maximum.
6.Attach the other end of the hose to a tank of LPG/
Propane and hand tighten.
7.Check all connections for leaks by wetting the fittings
with soapy water. Anywhere that bubbles appear or
grow indicates a leak in the connection. If a leak exists
at a fitting then turn off the tank valve and tighten the
fitting. Turn the gas back on and recheck with soapy
water again. If the leak continues or if the leak is not at
a fitting then do not use the generator and contact
customer service.