background image

 

PREPARATION OF THE GENERATOR FOR USE 

Using this Generator for the First-Time 

   

STOP!

 

 
The following section describes the required steps for preparing this generator for the first use. Failure to correctly perform 
these steps can damage this generator and/or shorten its life. If still unsure about how to perform any of these steps after 
reading this section, call  1-888-834-4218 Monday - Friday, 8 AM - 5 PM EST for customer service. 

 

If this generator is being used for the first time, the following few steps are required to prepare for operation: 

 

Step 1 - Add Oil 

 

THIS GENERATOR REQUIRES AT LEAST 13.5 FL OZ OF OIL (SAE10W-30) TO RUN. 

 

ADD OIL UNTIL IT IS ALMOST OVERFLOWING. THE LOW-OIL SENSOR IS VERY SENSITIVE AND THE ENGINE WILL NOT 
RUN IF THE OIL IS LOW. START WITH 13.5 OUNCES, THEN ADD MORE UNTIL ALMOST OVERFLOWING. 

 

TROUBLESHOOTING: IF THE GENERATOR WILL NOT START, DOUBLE CHECK THAT THE OIL LEVEL IS 
COMPLETELY FULL AND ALMOST OVERFLOWING. 

This  generator  requires  engine  oil  to  function.  Engine  oil  is  a  major  factor  affecting  engine  performance  and  service  life. 

When new from the package, this generator contains no oil in the engine crankcase. Add oil before operating this generator for the first 
time. When replenishing oil for subsequent use of this generator, always determine that this generator has the correct quantity of oil. 

 

To add oil to the engine crankcase: 

1.

 

Confirm that this generator is on a level surface. 

2.

 

Unscrew the oil filler/dipstick cap from the engine as illustrated in Figure 1 below. 

3.

 

Using a funnel, add high detergent motor oil to fill the engine crankcase to the correct quantity. SAE10W-30 oil is recommended for 

general use. When the engine crankcase is full and almost overflowing, the oil level should reach the lower lip of the oil filling opening 
as shown in Figure 2. 
4.

 

Replace the oil filler/dipstick cap and close the oil access panel. 

 

Figure 1    Unscrew the Dipstick Cap 

Figure 2 - Add Oil

Содержание GN1750D

Страница 1: ...s manual provides important information on proper operation maintenance Every effort has been made to ensure the accuracy of this manual These instructions are not meant to cover every possible condit...

Страница 2: ...een poweramerica com service and follow the instructions to register online following the instructions to register online Option 2 Fill out the form on the Warranty Card include in the box and return...

Страница 3: ...Generator 11 Step 1 Verify Oil Level 11 Step 2 Verify Gas Level 11 Step 3 Ground the Generator 11 STARTING THE GENERATOR 12 USING THE GENERATOR 13 AC Usage 13 DC Usage 14 SWITCHING BETWEEN GASOLINE P...

Страница 4: ...en to be defective in materials or workmanship under normal use during the ONE 1 YEAR warranty period Warranty repairs or replacements will be made without charge for parts or labor Parts replaced dur...

Страница 5: ...less AND may be present even if you do not see or smell gas Breathing this poison gas can lead to headaches dizziness drowsiness loss of consciousness and eventually death Usage This generator is not...

Страница 6: ...oors where gasoline fumes may reach flames and or sparks ank cap Loosen the cap slowly to relieve pressure in the fuel tank Avoid spilling fuel ank and immediately wipe it up before starting this gene...

Страница 7: ...7 In addition to the previously described safety information familiarize yourself with all safety and hazard placards on this generator...

Страница 8: ...ere are missing items call 1 888 834 4218 Monday Friday 8 AM 5 PM EASTERN Time for customer service DO NOT RETURN THIS GENERATOR TO THE RETAILER Item List DC connector wires for charging 12 Volt autom...

Страница 9: ...RT DOUBLE CHECK THAT THE OIL LEVEL IS COMPLETELY FULL AND ALMOST OVERFLOWING This generator requires engine oil to function Engine oil is a major factor affecting engine performance and service life W...

Страница 10: ...ed with the generator to the Propane Tank then connect the other end to the Gas Inlet Make sure the LPG Propane cylinder is vertical and securely positioned Step 3 Ground the Generator Ground this gen...

Страница 11: ...T Use only fresh UNLEADED gasoline with an octane rating of 87 or higher Never use old and or contaminated gasoline Never use a mixture of oil and gasoline Avoid getting dirt and or water in the fuel...

Страница 12: ...o snap back 7 If the engine fails to start repeat step 6 NOTE After repeated attempts to start the engine consult the troubleshooting guide before attempting again 8 Once the engine has started GRADUA...

Страница 13: ...e rated wattage for the generator A device s rated running wattage should be listed somewhere on the device itself and or in its manual If the wattage specification for a device is not available the w...

Страница 14: ...Gauge Amps Watts 120V Watts 240V 8 wire 10 wire 12 wire 14 wire 16 wire 2 5 300 600 NR 1000 600 375 250 5 600 1200 NR 500 300 200 125 7 5 900 1800 NR 350 200 125 100 10 1200 2400 NR 250 150 100 50 15...

Страница 15: ...eck Clean X Fuel Tank Verify Gas Level X Clean X Figure 7 Recommended maintenance schedule Cleaning Generator Always try to use this generator in a cool dry place If this generator becomes dirty the e...

Страница 16: ...ed every 6 months or for every 100 hours of use or when the oil has become dirty To drain the oil from generator 1 Place a bucket underneath this generator to catch oil as it drains 2 Unscrew the oil...

Страница 17: ...rk plug An E7TC spark plug such as NGK BP6HS is recommended 4 Measure the spark plug electrode gap with a gauge The gap should be 0 020 0 028in 0 5 0 7mm See Figure 9 5 If re using the spark plug use...

Страница 18: ...h No storage procedure required 1 to 2 months Fill with fresh gasoline and add gasoline stablizer 2 months to 1 year Empty the fuel tank See Emptying the Fuel Tank in the Maintenance Care section 1 ye...

Страница 19: ...on Pull the starter You should see a spark Engine will not start Engine will not start Engine will not start Engine runs but there is no electrical output Generator runs but does not support all conne...

Страница 20: ...20 Distributed by Green Power America LLC www Green PowerAmerica com All copyright is reserved by Green Power America LLC...

Отзывы: